Suppr超能文献

Evaluation of capillary electrophoretic techniques towards systematic toxicological analysis.

作者信息

Boone C M, Franke J P, de Zeeuw R A, Ensing K

机构信息

Department of Analytical Chemistry and Toxicology, State University of Groningen, The Netherlands.

出版信息

J Chromatogr A. 1999 Apr 9;838(1-2):259-72. doi: 10.1016/s0021-9673(99)00085-0.

Abstract

Two capillary electrophoresis (CE) methods were evaluated for their suitability in systematic toxicological analysis (STA). A test set of 25 barbiturates was analysed using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). Buffers used consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate, 50 mM sodium dodecyl sulphate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries using an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA as it influences the identification power (IP). To deal with the poor reproducibility of the migration time, we introduced the corrected effective mobility. Inter-day reproducibilities of the latter parameter were < 0.6% for CZE and < 0.5% for MEKC, using daily prepared buffers. The IP of the methods was expressed by calculation of the discriminating power and the mean list length. Data obtained were compared to gas chromatographic and high-performance liquid chromatographic data, and correlations between all methods were calculated. It was shown that little correlation exists between chromatographic and electrophoretic techniques. The results indicated that CE has a good identification power for the application in STA, especially when a combination of methods having a low correlation is used.

摘要

相似文献

1
Evaluation of capillary electrophoretic techniques towards systematic toxicological analysis.
J Chromatogr A. 1999 Apr 9;838(1-2):259-72. doi: 10.1016/s0021-9673(99)00085-0.
3
Interlaboratory reproducibility of mobility parameters in capillary electrophoresis for substance identification in systematic toxicological analysis.
Electrophoresis. 2002 Jan;23(1):67-73. doi: 10.1002/1522-2683(200201)23:1<67::AID-ELPS67>3.0.CO;2-#.
7
Is capillary electrophoresis a method of choice for systematic toxicological analysis?
Clin Chem Lab Med. 2003 Jun;41(6):773-81. doi: 10.1515/CCLM.2003.117.
8
Migration behavior and selectivity of sulfonamides in capillary electrophoresis.
J Chromatogr A. 1997 Dec 19;792(1-2):37-47. doi: 10.1016/s0021-9673(97)00614-6.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验