Boone C M, Franke J P, de Zeeuw R A, Ensing K
Department of Analytical Chemistry and Toxicology, University Center for Pharmacy, Groningen, The Netherlands.
Electrophoresis. 2000 May;21(8):1545-51. doi: 10.1002/(SICI)1522-2683(20000501)21:8<1545::AID-ELPS1545>3.0.CO;2-6.
The intra- and interinstrument reproducibilities of four capillary electrophoresis instruments were studied for identification purposes in systematic toxicological analysis (STA). A test set of 20 acidic test compounds and 5 reference compounds were analyzed for five days on each instrument using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). The buffers consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate and 50 mM sodium dodecyl sulfate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries at an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA. To deal with the poor reproducibility of the migration time, we recently introduced the corrected effective mobility. In this study, we investigated the intra- and interinstrument reproducibility of the migration time, the effective mobility, and the corrected effective mobility. Large differences in intra-instrument reproducibility were found when the migration time was used. The calculation of the effective mobility and the corrected effective mobility diminished these differences and enhanced the interinstrument reproducibility roughly by a factor 3. For (corrected) effective mobilities, intrainstrument reproducibilities were between 0.8-2.6% and interinstrument reproducibilities were between 3.2-3.9%.
为了系统毒理学分析(STA)中的鉴定目的,研究了四种毛细管电泳仪器的仪器内和仪器间重现性。使用毛细管区带电泳(CZE)和胶束电动色谱(MEKC),在每种仪器上对一组包含20种酸性测试化合物和5种参考化合物的测试集进行了为期五天的分析。缓冲液由pH值为8.4的90 mM硼酸盐(CZE)以及pH值为7.5的20 mM磷酸盐和50 mM十二烷基硫酸钠(MEKC)组成。所有分析均使用熔融石英毛细管,电场强度为52.6 kV/m。在STA中,使用可重现的鉴定参数非常重要。为了解决迁移时间重现性差的问题,我们最近引入了校正有效迁移率。在本研究中,我们研究了迁移时间、有效迁移率和校正有效迁移率的仪器内和仪器间重现性。当使用迁移时间时,发现仪器内重现性存在很大差异。有效迁移率和校正有效迁移率的计算减少了这些差异,并使仪器间重现性大致提高了3倍。对于(校正后的)有效迁移率,仪器内重现性在0.8 - 2.6%之间,仪器间重现性在3.2 - 3.9%之间。