Suppr超能文献

使用新开发的六自由度分析系统对可摘局部义齿进行功能移动性测量——磨牙人工牙尖斜度对义齿功能位移的影响

[Functional mobility measurement of removable partial dentures using newly-developed analyzing system in six degrees of freedom--effect of cusp inclination of molar artificial teeth on denture displacement in function].

作者信息

Takahashi J

机构信息

First Department of Prosthodontics, Faculty of Dentistry, Tokyo Medical and Dental University.

出版信息

Kokubyo Gakkai Zasshi. 1999 Mar;66(1):57-66. doi: 10.5357/koubyou.66.57.

Abstract

A measuring system to record three-dimensional displacement of removable partial dentures (RPDs) in six degrees of freedom has been developed. The system employed three pairs of photodiode and LED that were set up in a triangle. This system was capable of recording the in vivo RPD displacement with a recording sensitivity of 0.1 mm. In vivo displacement of upper RPDs with unilateral distal extension saddle was investigated using this measuring system to determine the effect of artificial cusp inclination of molar teeth on denture mobility. Two groups of different artificial dentition were switched to be attached to each of three experimental RPDs. The artificial teeth with cusp inclinations were calibrated to contact with opposing natural dentition during lateral grinding of the mandible, while the other artificial teeth were prepared to disclude with the mandibular teeth (flat-cusp group). Displacement range and average position of a reference point at the first molar of the RPDs during mastication were measured and analyzed as a function of the cusp inclination and the test food. As a result, the average displacement of the RPDs toward the edentulous ridge was smaller in the cusp group than that in the flat-cusp group, while the range of horizontal displacement in the buccal-palatal direction was greater in the former group than the latter. The denture wearers demonstrated typical grinding strokes at the end of the closing phase of the mandiblar movements when they chewed a peanut, which was attributed to a wide range of horizontal displacement of the dentures.

摘要

已开发出一种用于记录可摘局部义齿(RPD)在六个自由度上三维位移的测量系统。该系统采用三对光电二极管和发光二极管,它们呈三角形设置。该系统能够以0.1毫米的记录灵敏度记录体内RPD位移。使用该测量系统研究了带有单侧远中伸展鞍基的上颌RPD的体内位移,以确定磨牙人工牙尖倾斜度对义齿移动性的影响。将两组不同的人工牙列切换后分别连接到三个实验性RPD上。对具有牙尖倾斜度的人工牙进行校准,使其在下颌侧向研磨时与相对的天然牙列接触,而另一组人工牙则制备成与下颌牙无接触(平尖组)。测量并分析了RPD第一磨牙处参考点在咀嚼过程中的位移范围和平均位置,作为牙尖倾斜度和测试食物的函数。结果,牙尖组中RPD向无牙嵴方向的平均位移小于平尖组,而前者在颊腭方向的水平位移范围大于后者。当义齿佩戴者咀嚼花生时,在下颌运动的闭合阶段末期表现出典型的研磨动作,这归因于义齿较大的水平位移范围。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验