Rhodes M C, Margolis R H, Hirsch J E, Napp A P
Northland ENT Associates, Duluth; the Department of Otolaryngology, University of Minnesota, Minneapolis, USA.
Otolaryngol Head Neck Surg. 1999 Jun;120(6):799-808. doi: 10.1016/S0194-5998(99)70317-7.
Patients in the neonatal intensive care unit were tested by hearing screening tests including auditory brain stem response (ABR), transient and distortion-product otoacoustic emissions (TEOAEs and DPOAEs), and acoustic stapedius reflex (ASR), and by middle ear function tests including multifrequency tympanometry and pneumatic otoscopy. Pass rates on hearing tests were 75% to 89%. TEOAEs produced the lowest pass rate, and DPOAEs the highest. TEOAE, DPOAE, or ASR testing followed by ABR testing of initial failures produced pass rates of about 90%. The most efficient combination was DPOAEs followed by ABR. Pass rates tended to decrease with age. Of patients who failed 226-Hz and 678-Hz tympanometry, 30% to 67% passed hearing tests, suggesting a high false-positive rate for these immittance tests. The 3 ears that failed the 1000-Hz tympanogram failed all hearing tests. Many ears were abnormal by pneumatic otoscopy but passed hearing tests, suggesting that the usual ear examination criteria may not apply to infants.
新生儿重症监护病房的患者接受了听力筛查测试,包括听性脑干反应(ABR)、瞬态和畸变产物耳声发射(TEOAEs和DPOAEs)以及镫骨肌声反射(ASR),还接受了中耳功能测试,包括多频鼓室图和鼓气耳镜检查。听力测试的通过率为75%至89%。TEOAEs的通过率最低,DPOAEs的通过率最高。对初次测试未通过的患者先进行TEOAE、DPOAE或ASR测试,然后进行ABR测试,通过率约为90%。最有效的组合是先进行DPOAEs测试,然后进行ABR测试。通过率往往随着年龄的增长而降低。在226赫兹和678赫兹鼓室图测试未通过的患者中,30%至67%的人听力测试通过,这表明这些声导抗测试的假阳性率很高。1000赫兹鼓室图测试未通过的3只耳朵所有听力测试均未通过。许多耳朵通过鼓气耳镜检查显示异常,但听力测试通过,这表明通常的耳部检查标准可能不适用于婴儿。