Suppr超能文献

1999年加里·J·贝克尔青年研究者奖。在猪模型中进行磁共振引导下经颈静脉肝内门体分流术置管。

1999 Gary J. Becker Young Investigator Award. MR-guided transjugular portosystemic shunt placement in a swine model.

作者信息

Kee S T, Rhee J S, Butts K, Daniel B, Pauly J, Kerr A, O'Sullivan G J, Sze D Y, Razavi M K, Semba C P, Herfkens R J, Dake M D

机构信息

Department of Radiology, Stanford University School of Medicine, California, USA.

出版信息

J Vasc Interv Radiol. 1999 May;10(5):529-35. doi: 10.1016/s1051-0443(99)70078-3.

Abstract

PURPOSE

To evaluate the performance of portal venous puncture with use of magnetic resonance (MR) guidance, and to place a transjugular intrahepatic portosystemic shunt (TIPS) in a swine model.

MATERIALS AND METHODS

A study of 12 swine was performed to evaluate the ability of interventional MR imaging to guide portal vein puncture and TIPS placement. Six swine had catheters placed in the right hepatic vein under C-arm fluoroscopy. A nitinol guide wire was left in the vein and the animals were then moved into an open configuration MR imaging unit. A TIPS needle set was used to puncture the portal vein using MR fluoroscopy. The animals were transferred to the C-arm, and venography confirmed portal vein puncture. A follow-up study was performed in six additional swine to place a TIPS using only MR imaging guidance. MR tracking was used to advance a catheter from the right atrium into the inferior vena cava. Puncture of the portal vein was performed and a nitinol stent was placed, bridging the hepatic parenchyma. MR venogram confirmed placement.

RESULTS

Successful portal vein puncture was achieved in all animals. The number of punctures required decreased from 12 in the first animal to a single puncture in the last eight swine. A stent was successfully placed across the hepatic tract in all six swine.

CONCLUSIONS

Real-time MR imaging proved to be a feasible method to guide portal vein puncture and TIPS placement in pigs.

摘要

目的

评估在磁共振(MR)引导下进行门静脉穿刺的性能,并在猪模型中放置经颈静脉肝内门体分流术(TIPS)。

材料与方法

对12头猪进行研究,以评估介入性MR成像引导门静脉穿刺和TIPS放置的能力。6头猪在C形臂荧光透视引导下将导管置于右肝静脉。在静脉内留置一根镍钛诺导丝,然后将动物转移至开放式MR成像单元。使用TIPS穿刺针套装在MR透视引导下穿刺门静脉。将动物转移至C形臂,静脉造影证实门静脉穿刺成功。另外6头猪仅在MR成像引导下进行TIPS放置的随访研究。使用MR追踪技术将导管从右心房推进至下腔静脉。进行门静脉穿刺并放置镍钛诺支架,跨越肝实质。MR静脉造影证实支架放置成功。

结果

所有动物均成功实现门静脉穿刺。所需穿刺次数从第一头动物的12次减少至最后8头猪的单次穿刺。所有6头猪均成功在肝内放置支架。

结论

实时MR成像被证明是在猪中引导门静脉穿刺和TIPS放置的可行方法。