A rapid and reliable method of carboxyhemoglobin determination is described. Hemoglobin-bound carbon monoxide is released chemically into a continuous nitrogen stream and transported to an infrared gas analyser. The total amount of released CO is determined electronically. 100% CO Hb values are obtained in the same way from diluted blood samples after flushing with pure CO in special saturation vessels. The method described yields results with a standard deviation of +/- 2.5%.
本文描述了一种快速可靠的碳氧血红蛋白测定方法。与血红蛋白结合的一氧化碳通过化学方法释放到连续的氮气流中,并传输至红外气体分析仪。释放的一氧化碳总量通过电子方式测定。在特殊的饱和容器中用纯一氧化碳冲洗稀释后的血样,以同样的方式获得100%碳氧血红蛋白值。所述方法得出的结果标准偏差为±2.5%。