Thubrikar M J, Konstantinov I E, Selim G A, Gong G G, Fowler B, Robicsek F
Heineman Medical Research Laboratory, Carolinas Medical Center, Charlotte, North Carolina.
J Heart Valve Dis. 1999 May;8(3):242-53.
The influence of sizing on the function of a porcine aortic valve after its implantation using the free-hand technique in the subcoronary position was investigated.
Dynamic function and leaflet configuration of the valve (n = 16) were first analyzed in its natural aortic root in a left heart simulator at 120/80 mmHg pressure and 4 l/min cardiac output. The valve was then implanted in the recipient porcine aortic root and re-studied. Three groups were investigated: group I (n = 4) comprised of 1-2 mm smaller donor aortic valve than the recipient; group II (n = 8) 3-4 mm smaller; and group III (n = 4) 5-7 mm smaller. Orifice area (OA), systolic and diastolic configurations of the leaflets, pattern and timing of leaflet opening and closure, commissural movement, pressure gradient and valvular regurgitation were analyzed.
In the intact donor aortic root, average expansion of the aorta at the commissures, for a pressure change from 0 to 80 mmHg, was about 42%. This was reduced significantly in all assemblies. Group I showed a 34% reduction in OA, and excessive leaflet bending; there was no aortic insufficiency (AI) or pressure gradient across the valve. In group III there was a lesser reduction in OA and reduced leaflet bending, but two of four valves had AI. In group II, the reduction in OA was only 13%, there was less leaflet bending, and no AI.
The donor valve 3-4 mm smaller than the recipient seems an optimal match. The current practice of using the same size donor as recipient may be responsible for excessive leaflet bending and may be implicated in early deterioration of the homograft.
研究在冠状动脉下位置采用徒手技术植入猪主动脉瓣后,瓣膜尺寸对其功能的影响。
首先在左心模拟器中,于120/80 mmHg压力和4 l/min心输出量条件下,对16个瓣膜在其自然主动脉根部的动态功能和瓣叶形态进行分析。然后将瓣膜植入受体猪的主动脉根部并再次研究。研究分为三组:第一组(n = 4),供体主动脉瓣比受体小1 - 2 mm;第二组(n = 8),小3 - 4 mm;第三组(n = 4),小5 - 7 mm。分析瓣口面积(OA)、瓣叶的收缩期和舒张期形态、瓣叶开闭模式和时间、交界运动、压力梯度和瓣膜反流情况。
在完整的供体主动脉根部,当压力从0 mmHg变化到80 mmHg时,交界处主动脉的平均扩张约为42%。在所有组装体中,这种扩张均显著降低。第一组OA降低34%,瓣叶过度弯曲;瓣膜无主动脉瓣关闭不全(AI)或压力梯度。第三组OA降低程度较小,瓣叶弯曲减少,但四个瓣膜中有两个出现AI。第二组OA仅降低13%,瓣叶弯曲较少,且无AI。
比受体小3 - 4 mm的供体瓣膜似乎是最佳匹配。目前使用与受体相同尺寸供体的做法可能导致瓣叶过度弯曲,并可能与同种异体移植物的早期退变有关。