Calamante F, Thomas D L, Pell G S, Wiersma J, Turner R
RCS Unit of Biophysics, Institute of Child Health, University College London Medical School, United Kingdom.
J Cereb Blood Flow Metab. 1999 Jul;19(7):701-35. doi: 10.1097/00004647-199907000-00001.
Magnetic resonance imaging techniques measuring CBF have developed rapidly in the last decade, resulting in a wide range of available methods. The most successful approaches are based either on dynamic tracking of a bolus of a paramagnetic contrast agent (dynamic susceptibility contrast) or on arterial spin labeling. This review discusses their principles, possible pitfalls, and potential for absolute quantification and outlines clinical and neuroscientific applications.
在过去十年中,用于测量脑血流量(CBF)的磁共振成像技术发展迅速,催生了一系列可用方法。最成功的方法要么基于对顺磁性造影剂团注的动态追踪(动态磁敏感对比),要么基于动脉自旋标记。本综述讨论了它们的原理、可能存在的问题以及绝对定量的潜力,并概述了临床和神经科学应用。