Suppr超能文献

供体眼库眼角膜的新型筛查方法。

New screening methods for donor eye-bank eyes.

作者信息

Terry M A, Ousley P J

机构信息

Lions Eye Bank of Oregon Research Laboratory, Portland, USA.

出版信息

Cornea. 1999 Jul;18(4):430-6. doi: 10.1097/00003226-199907000-00007.

Abstract

PURPOSE

Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening.

METHODS

Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results.

RESULTS

The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD.

CONCLUSIONS

Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.

摘要

目的

目前用于角膜移植供体眼筛选的方法在排除地形图异常的角膜方面并不总是有效。我们使用Orbscan来确定角膜厚度图是否可用作供体组织筛选技术。

方法

用Orbscan测量了40只眼库眼,并生成了角膜厚度图。将每张图的平均中央角膜厚度测量值与最薄的周边中部厚度读数进行比较。然后将一名接受准分子激光原位角膜磨镶术(PRK)的供体的两只眼和一名圆锥角膜供体的两只眼与正常供体眼的结果进行比较。

结果

对照组周边中部最薄角膜厚度与中央角膜厚度的平均差值为0.040±0.026mm。接受PRK的供体的眼睛由于中央角膜变薄,中央和周边中部厚度之间的差异更大,右眼差异为0.154mm,左眼差异为0.106mm。圆锥角膜供体的眼睛周边中部角膜比中央薄,表明有偏心、扩张的圆锥。接受PRK的供体和圆锥角膜供体的眼睛中央与周边中部的厚度差异与对照组相比相差>2个标准差。

结论

通过Orbscan角膜厚度测绘并与正常范围比较,可以筛选出影响中央和周边中部角膜厚度关系的疾病或手术情况。