Suppr超能文献

Total anorectal reconstruction by double graciloplasty: experience with delayed, selective use of implantable pulse generators.

作者信息

Violi V, Roncoroni L, Boselli A S, De Cesare C, Livrini M, Peracchia A

机构信息

Department of Surgery, General Surgical Clinic, University of Parma Medical School, Ospedale Maggiore, Via Gramsci, 14, I-43100 Parma, Italy,

出版信息

Int J Colorectal Dis. 1999 Aug;14(3):164-71. doi: 10.1007/s003840050204.

Abstract

This study reports our experience with total anorectal reconstruction (TAR), supported at a later phase, whenever necessary, by an implantable pulse generator. Thirteen patients underwent total anorectal reconstruction by double graciloplasty, diverting loop colostomy, and implantation of temporary electrodes. External-source, short-term, intermittent electrostimulation and biofeedback were used for neosphincter voluntary control training. After abdominal stoma closure, 6 months after initial surgery in disease-free patients, functional results were evaluated by a scoring system and anomanometry. A pulse generator was implanted whenever continence was judged unsatisfactory. After continuous electrostimulation training, neosphincter function was reassessed. Major graciloplasty complications (partial muscle necrosis and perineal colostomy necrosis) were treated successfully by surgery. One death of myocardial infarction occurred after discharge. Three patients refused further surgery. One patient did not undergo abdominal stoma closure because of early hepatic metastases. Functional evaluation after closure (eight patients) showed the following results: two "excellent" (no pulse generator implanted), three "good" (two stimulator implantations, with an "excellent" result), two "fair", and one "poor" (3 implantations, with a "good" result). In addition to improving clinical results (P=0.042), resting anal pressures were also increased significantly by active an implantable pulse generator (P=0.043). Although stimulators, whenever implanted, improved the neosphincter function, delayed, selective use of these in some cases rendered an implantable pulse generator either unnecessary from a functional viewpoint or redundant because of cancer recurrence or infectious complications. Drawbacks to the procedure were poor patient compliance to neosphincter training and to multiple surgical procedures, and excessive wasting of human resources during training for intermittent electrostimulation and biofeedback.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验