• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

作者信息

Wada H, Fukunaga S, Watari M, Sakai H, Sugawara Y, Ochikubo H, Imai K, Shibamura H, Orihashi K, Sueda T, Matsuura Y

机构信息

First Department of Surgery, Hiroshima University School of Medicine, Minamiku, Japan.

出版信息

Artif Organs. 1999 Aug;23(8):741-6. doi: 10.1046/j.1525-1594.1999.06414.x.

DOI:10.1046/j.1525-1594.1999.06414.x
PMID:10463500
Abstract

We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial shunt to achieve left-right balance. We have conducted numerical simulation, a mock test, and an acute animal experiment to analyze left-right heart balance during ERTAH operation. Numerical simulation was performed under conditions in which the flow of the left artificial heart was fixed at 6 L/min, the flow of the right artificial heart was varied from 4.8 to 6 L/min, and the interatrial resistance was also varied. The relationship between the interatrial shunt flow rate and the output of the left and right artificial hearts was balanced when the flow of the right artificial heart was at 5.45 L/min. In a mock test, 2 DeBakey roller pumps were connected to the left and right sides of a Donovan mock circulatory system, and an interatrial shunt was created between the inlet ports of the left and right roller pumps. The interatrial resistance of the mock system was varied from 7.7, to 4.3, and to 2.9 mm Hg x min/L when the inner diameter of the interatrial shunt was 6, 8, and 10 mm, respectively. As in the mock test, 2 roller pumps were used to bypass the right and left hearts of a goat weighing 60 kg. The flow rate of the left heart was almost constant (4.7 L/min). The flow of the right heart was approximately 4.1 L/min when the interatrial shunt flow rate was zero. A leading consideration was that the left to left shunt through the bronchial arteries in this goat was approximately 0.6 L/min. In developing the ERTAH, we considered that creating an interatrial shunt between the inlet ports of the ERTAH as well as making a difference between the chamber volumes might be effective in balancing the left-right sides of the artificial heart.

摘要

相似文献

1
Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.
Artif Organs. 1999 Aug;23(8):741-6. doi: 10.1046/j.1525-1594.1999.06414.x.
2
Newly designed eccentric roller type total artificial heart.新设计的偏心滚轮式全人工心脏。
Hiroshima J Med Sci. 2000 Mar;49(1):7-14.
3
Eccentric roller type total artificial heart creating interatrial shunt.产生房间隔分流的偏心滚轮式全人工心脏。
Artif Organs. 2000 Aug;24(8):671-5. doi: 10.1046/j.1525-1594.2000.06602.x.
4
Trial manufacture of eccentric roller type total artificial heart.偏心滚轴式全人工心脏的试制
Artif Organs. 1997 Jul;21(7):735-8. doi: 10.1111/j.1525-1594.1997.tb03732.x.
5
In vitro analysis of an atrial shunt in balancing an electrohydraulic total artificial heart.用于平衡电动液压全人工心脏的心房分流器的体外分析
ASAIO Trans. 1990 Jul-Sep;36(3):M254-7.
6
Right-left ventricular balance in implanted electrically powered artificial hearts.
ASAIO Trans. 1990 Jul-Sep;36(3):M287-90.
7
In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system.
ASAIO J. 1997 Sep-Oct;43(5):M619-25.
8
Right-left ventricular output balance in the totally implantable artificial heart.
Int J Artif Organs. 1991 Jun;14(6):359-64.
9
Eccentric roller type total artificial heart designed for implantation.设计用于植入的偏心滚轮式全人工心脏。
Artif Organs. 1998 Jun;22(6):451-7. doi: 10.1046/j.1525-1594.1998.06153.x.
10
An atrial hydraulic shunt in a total artificial heart. A balance mechanism for the bronchial shunt.全人工心脏中的心房液压分流器。支气管分流器的平衡机制。
ASAIO J. 1993 Jul-Sep;39(3):M213-7.