Gay C, Collins J, Gebicki J M
School of Biological Sciences, Macquarie University, Sydney, 2109, Australia.
Anal Biochem. 1999 Sep 10;273(2):149-55. doi: 10.1006/abio.1999.4208.
A range of hydroperoxides were reduced by ferrous ions in acid solutions and the amount of ferric product was measured as a xylenol orange complex at 560 nm. Dilute sulfuric acid, 50% acetic acid, and acidified 90% methanol proved to be suitable solvents. The color developed within 15 min and was stable for several hours in most solvents. The apparent molar absorption coefficients (epsilon(app)) of H(2)O(2) and of the t-butyl, cumene, bovine serum albumin, and linoleate hydroperoxides were measured, using known hydroperoxide concentrations determined independently by an iodometric assay. The epsilon(app) values differed significantly and depended on the hydroperoxide, the solvent, and the source of the xylenol orange. The numbers of Fe(3+) ions formed by a range of hydroperoxides in different solvents showed that H(2)O(2) gave 2.5, t-butyl and cumene hydroperoxides 5, and the other hydroperoxides 2 Fe(3+) ions per -OOH group. This general finding allows the determination of approximate hydroperoxide concentrations even in chemically complex systems. Accurate measurements require knowledge of the nature of the hydroperoxide and its epsilon(app) and careful control of the assay conditions. However, the convenience of the assay makes it potentially useful in a variety of applications.
一系列氢过氧化物在酸性溶液中被亚铁离子还原,并在560nm处测量生成的铁离子产物与二甲酚橙形成的络合物的量。稀硫酸、50%乙酸和酸化的90%甲醇被证明是合适的溶剂。在大多数溶剂中,颜色在15分钟内显色并在数小时内稳定。使用通过碘量法独立测定的已知氢过氧化物浓度,测量了H₂O₂以及叔丁基、异丙苯、牛血清白蛋白和亚油酸酯氢过氧化物的表观摩尔吸收系数(ε(app))。ε(app)值有显著差异,并且取决于氢过氧化物、溶剂和二甲酚橙的来源。一系列氢过氧化物在不同溶剂中形成的Fe(3+)离子数量表明,每个-OOH基团,H₂O₂生成2.5个Fe(3+)离子,叔丁基和异丙苯氢过氧化物生成5个,其他氢过氧化物生成2个Fe(3+)离子。这一普遍发现使得即使在化学组成复杂的体系中也能测定氢过氧化物的大致浓度。准确测量需要了解氢过氧化物的性质及其ε(app),并仔细控制测定条件。然而,该测定方法的便利性使其在各种应用中具有潜在的实用性。