Suppr超能文献

术者年龄对诊断准确性的影响:一项使用根管锉长度评估的研究

The effects of developer age on diagnostic accuracy: a study using assessment of endodontic file length.

作者信息

Syriopoulos K, Sanderink G C, Velders X L, van Ginkel F C, van der Stelt P F

机构信息

Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), The Netherlands.

出版信息

Dentomaxillofac Radiol. 1999 Sep;28(5):311-5. doi: 10.1038/sj/dmfr/4600464.

Abstract

OBJECTIVES

To examine the effects of developer age on image quality.

METHODS

Endodontic files, size 10 and 15, were placed in upper and lower molars and premolars up to the root apex or 1.5 mm short. A series of radiographs were made with each of three film types: Dentus M2 (Agfa-Gevaert, Mortsel, Belgium), Ektaspeed Plus and Ultra-speed (Kodak Eastman Co, Rochester, USA). The films were processed bi-weekly using the same Agfa chemicals (Heraeus Kulzer, Dormagen, Germany) over a 6-week period. An additional set of Dentus M2 films was processed using Periomat chemicals (Dürr Dental, Bietigheim-Bissingen, Germany). The films were viewed by eight dentists who rated the position of the tip of the file using a 5-point confidence scale. ROC data were analysed by means of analysis of variance. Az value was the dependent variable, whereas observer age group was entered as between subject factor. The null hypothesis was rejected when P<0.05.

RESULTS

The diagnostic accuracies of the three films were comparable during the first 4 weeks. In the sixth week Ultra-speed was significantly better than the other two films (P=0.046). The Periomat chemicals showed significantly greater consistency than the Agfa chemicals (P=0.004). Developer exhaustion significantly affected the performance of the older observers (P=0.008), especially when Agfa chemicals and file size 10 were used.

CONCLUSION

Agfa chemicals older than 4 weeks significantly affect the assessment of endodontic file length. In earlier stages there are no significant differences between the three films tested. Dentus M2 and Ektaspeed Plus films should be used as they require lower exposures.

摘要

目的

研究显影剂使用时长对影像质量的影响。

方法

将10号和15号根管锉分别置于上下颌磨牙及前磨牙中,直至根尖或短于根尖1.5毫米处。使用三种胶片类型(Dentus M2(爱克发 - 吉华集团,比利时莫策尔)、Ektaspeed Plus和超高速胶片(柯达伊士曼公司,美国罗切斯特))分别拍摄一系列X光片。在6周的时间里,每两周使用相同的爱克发化学药剂(贺利氏古莎公司,德国多马根)冲洗一次胶片。另外一组Dentus M2胶片使用Periomat化学药剂(迪尔牙科,德国比蒂希海姆 - 比辛根)冲洗。由八位牙医观察这些胶片,并使用5级置信量表对锉尖位置进行评分。通过方差分析对ROC数据进行分析。Az值为因变量,观察者年龄组作为组间因素纳入分析。当P<0.05时,原假设被拒绝。

结果

在最初4周内,三种胶片的诊断准确性相当。在第6周时,超高速胶片明显优于其他两种胶片(P = 0.046)。Periomat化学药剂的一致性明显高于爱克发化学药剂(P = 0.004)。显影剂耗尽对年长观察者的表现有显著影响(P = 0.008),尤其是在使用爱克发化学药剂和10号根管锉时。

结论

使用时长超过4周的爱克发化学药剂会显著影响根管锉长度的评估。在早期阶段,所测试的三种胶片之间没有显著差异。应使用Dentus M2和Ektaspeed Plus胶片,因为它们所需的曝光量较低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验