Klotch D W, Gal T J, Gal R L
Division of Otolaryngology, Department of Surgery, University of South Florida, Tampa 33606, USA.
Otolaryngol Head Neck Surg. 1999 Oct;121(4):388-92. doi: 10.1016/S0194-5998(99)70226-3.
Reconstruction of mandibular defects with a variety of alloplastic materials during a 22-year period was reviewed. Outcomes were examined to determine whether specific plating technology affected the incidence of plate-related complications including plate exposure, plate fracture, and plate removal. Repair with the miniplate, reconstruction plate, titanium hollow screw reconstruction plate, and locking reconstruction plate was evaluated. Although the incidence of plate fractures has decreased, there was no significant change in the rate of plate exposure. Recurrent disease was noted to be a significant contributing factor in the development of plate-related complications.
回顾了22年间使用多种异体材料重建下颌骨缺损的情况。对结果进行了检查,以确定特定的接骨板技术是否会影响与接骨板相关的并发症的发生率,包括接骨板暴露、接骨板骨折和接骨板取出。评估了微型接骨板、重建接骨板、钛空心螺钉重建接骨板和锁定重建接骨板的修复情况。尽管接骨板骨折的发生率有所下降,但接骨板暴露率没有显著变化。复发性疾病被认为是与接骨板相关并发症发生的一个重要因素。