Experimental studies on environmental contamination with infected blood during haemodialysis.

出版信息

J Hyg (Lond). 1975 Feb;74(1):133-48. doi: 10.1017/s0022172400046799.

Abstract

To assess the relative importance of different postulated modes of spread of hepatitis B in dialysis units, blood charged with various tracer organisms was used in simulated haemodialysis runs in four laboratories, and the resulting contamination of equipment and environment was measured semi-quantitatively. Some airborne spread of the tracer organism occurred when tubing containing contaminated blood was needled as the "patient" went on and came off the dialyser. Virtually no small airborne particles could be demonstrated however in simulated emergencies in which a blood line was disconnected, or even when bottles of blood were dropped on to a hard floor from a height of 2 metres. Bacillus globigii spores from contaminated blood leaked in small numbers into the dialysing fluid through apparently intact coils. T3 phage, with a particle size of the same order as hepatitis B virus, passed in small quantities through the membrane of a Kiil dialyser from blood to dialysing fluid and also in the reverse direction when added to the header tank. A number of other dialysers were also permeable to phage. Visual assessment of the appropriate moment for inserting the venous line into the "patient" at the onset of dialysis was shown to be unreliable, as the displaced fluid from the end of the venous line was already contaminated before it contained visible red blood cells. Considerable contamination of exposed surfaces and of the buttons on the proportionating unit cabinet occurred. Minor visible splashing of blood was a common-place of the laboratory experiments and was shown to be also a common event during routine haemodialysis in two of the dialysis units taking part in the studies.

摘要

相似文献

1
Experimental studies on environmental contamination with infected blood during haemodialysis.
J Hyg (Lond). 1975 Feb;74(1):133-48. doi: 10.1017/s0022172400046799.
3
Aerosol and Surface Deposition Characteristics of Two Surrogates for Bacillus anthracis Spores.
Appl Environ Microbiol. 2016 Oct 27;82(22):6682-6690. doi: 10.1128/AEM.02052-16. Print 2016 Nov 15.
4
An assessment of the airborne route in hepatitis B transmission.
Ann N Y Acad Sci. 1980;353:157-66. doi: 10.1111/j.1749-6632.1980.tb18918.x.
7
Relationship between dialyser type and signs and symptoms.
Nephrol Dial Transplant. 1993;8 Suppl 2:30-9. doi: 10.1093/ndt/8.supp2.30.
8
Particle release from haemodialysers.
Int J Artif Organs. 1990 Dec;13(12):803-8.
9
Study of membrane permeability in haemodialysis.
Br Med J. 1970 Mar 28;1(5699):786-7. doi: 10.1136/bmj.1.5699.786.
10
Contamination of the environment by special purpose centrifuges used in clinical laboratories.
J Clin Pathol. 1981 Oct;34(10):1114-23. doi: 10.1136/jcp.34.10.1114.

本文引用的文献

2
Hepatitis in dialysis units in the United Kingdom.
Br Med J. 1972 Jul 8;3(5818):94-9. doi: 10.1136/bmj.3.5818.94.
3
Control of hepatitis in dialysis units.
Br Med Bull. 1972 May;28(2):169-79. doi: 10.1093/oxfordjournals.bmb.a070919.
4
Possible airborne spread of serum-hepatitis virus within a haemodialysis unit.
Lancet. 1971 Oct 16;2(7729):849-50. doi: 10.1016/s0140-6736(71)90223-6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验