Suppr超能文献

Diagnostic criteria for detection of postinfarction ischemia by quantitative analysis of stepwise dobutamine radionuclide ventriculography.

作者信息

Ceriani L, Verna E, Giovanella L, Binaghi G, Garancini S

机构信息

Department of Nuclear Medicine, Ospedale di Circolo e Fondazione Macchi, University Hospital - Varese, Italy.

出版信息

J Nucl Cardiol. 1999 Sep-Oct;6(5):514-21. doi: 10.1016/s1071-3581(99)90024-7.

Abstract

BACKGROUND

Application of the traditional diagnostic criteria validated for exercise testing may be inappropriate when dobutamine infusion is associated with radionuclide ventriculography (RNV). The objective of this study was to establish appropriate diagnostic criteria for evaluation of dobutamine stress testing with RNV for the detection of early postinfarction ischemia.

METHODS

RNV was performed at baseline and during dobutamine infusion in 10 control subjects and in 30 patients who were studied within 1 week after uncomplicated myocardial infarction. Several quantitative parameters including left ventricular ejection fraction (EF), regional EF, and absolute change in global and regional EF were tested. In addition, regional wall-motion changes were scored by visual analysis. The limit of normal response for each quantitative parameter was defined as the 95th percentile of the distribution observed in control subjects. On the basis of predischarge clinical evaluation and exercise stress testing, patients were grouped as having evidence of residual ischemia (group 1, 15 patients) or no evidence of ischemia (group 2, 15 patients). Sensitivity, specificity, and accuracy in the detection of postinfarction ischemia were calculated for each parameter, and empiric receiver-operating characteristic curves were generated.

RESULTS

The limits of the normal response to dobutamine infusion in the control subjects were found to be a 7.5% and a 12.5% increase in global EF at low and high dose, respectively. Median baseline EF was significantly lower in patients than in control subjects (Mann-Whitney U test: P < .001). There were no differences in resting EF between group 1 and group 2 patients. However, median high-dose EF and increase in EF were significantly lower in group 1 as compared with group 2 patients (56% vs 72% and 5% vs 17%, respectively; Mann-Whitney U test: P < .0001 for both). A biphasic (up-and-down) response with initial increase at low dose followed by decrease or no change in EF at high dose was observed in 66% of group 1 patients and only in 13% of group 2 subjects. The best criterion for detection of postinfarction ischemia was a change of <12.5% in global EF at high-dose dobutamine infusion, with 80% predictive accuracy. The traditional criterion, a change of <5 % or a decrease in EF, yielded an accuracy of only 63%. The association of a change of <12.5% with a biphasic response increased accuracy to 87%, with a sensitivity of 93% and a specificity of 80%. Quantitative regional wall motion analysis showed greater diagnostic accuracy than visual wall motion scoring (83% vs 70%).

CONCLUSIONS

Application of appropriate criteria and stepwise quantitative analysis of RNV during dobutamine infusion may increase accuracy in the detection of early postinfarction ischemia.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验