Suppr超能文献

根管充填后细菌渗漏与染料渗漏的比较

Bacterial leakage versus dye leakage in obturated root canals.

作者信息

Barthel C R, Moshonov J, Shuping G, Orstavik D

机构信息

Department of Operative and Preventive Dentistry and Endodontics, Charité, Humboldt University, Berlin, Germany.

出版信息

Int Endod J. 1999 Sep;32(5):370-5. doi: 10.1046/j.1365-2591.1999.00235.x.

Abstract

AIM

The aim of this study was to compare in vitro bacterial and dye leakage tests, commonly used to determine the seal of root canal fillings.

METHODOLOGY

Ninety-six single-rooted teeth had their crowns removed at the cemento-enamel junction and their roots instrumented to ISO size 60 within 1 mm of the apex. Three groups of 30 roots were obturated by lateral condensation using gutta-percha and one or other of the sealers. AH26, Ketac Endo, or Roth's 801 sealer. Three roots were used as negative controls and three roots as positive controls. The roots were then exposed at their coronal end first for 38 days to soy broth containing Staphylococcus epidermidis and thereafter for 48 h to basic fuchsin. Bacterial leakage was recorded when the challenging organism could be recovered from the apical end. Dye leakage was checked by microscopy of transverse sections of the apical tip at the end of the experiment.

RESULTS

For the bacterial experiment, there was no significant difference amongst the three sealer groups. The dye experiment showed significantly greater leakage in the AH26 compared to the Ketac Endo group. No correlation between the results of the two tests could be seen.

CONCLUSIONS

The results of this study suggest that the molecular size of the penetrating agent may not be the relevant parameter when attempting to determine an appropriate test for the sealability of root canal fillings.

摘要

目的

本研究旨在比较常用于确定根管充填物封闭性的体外细菌渗漏试验和染料渗漏试验。

方法

96颗单根牙在牙骨质-釉质界处截冠,将根管预备至根尖孔1mm范围内的ISO 60号。3组,每组30个根管,采用侧向加压法用牙胶尖和以下其中一种封闭剂进行充填:AH26封闭剂、Ketac Endo封闭剂或Roth's 801封闭剂。3个根管用作阴性对照,3个根管用作阳性对照。然后先将根管冠端暴露于含有表皮葡萄球菌的大豆肉汤中38天,之后再暴露于碱性品红中48小时。当能从根尖端分离出受试微生物时,记录细菌渗漏情况。实验结束时,通过对根尖横切面进行显微镜检查来检测染料渗漏情况。

结果

在细菌实验中,3种封闭剂组之间无显著差异。染料实验显示,与Ketac Endo组相比,AH26组的渗漏明显更多。未发现两种试验结果之间存在相关性。

结论

本研究结果表明,在试图确定一种合适的根管充填物封闭性检测方法时,渗透剂的分子大小可能不是相关参数。