Ramage I J, Chapman J P, Hollman A S, Elabassi M, McColl J H, Beattie T J
Renal Unit and Department of Diagnostic Imaging, Royal Hospital for Sick Children, Glasgow, Scotland.
J Pediatr. 1999 Dec;135(6):765-7. doi: 10.1016/s0022-3476(99)70099-5.
To compare the accuracy of cultures of urine obtained by clean-catch urine (CCU) collection and suprapubic aspiration (SPA) in infants.
Prospective case series undertaken in a pediatric teaching hospital and associated neonatal unit. Fifty-eight paired urine cultures (CCU collection and SPA) were obtained from 49 infants with suspected urinary tract infection. The primary outcome measure was the presence or absence of significant bacteriuria on both CCU collection and SPA; secondary outcome measures were the success of SPA with ultrasound guidance compared with aspiration without ultrasound guidance. Statistical analysis was done by using a chi(2) test.
A false-positive rate of 5% and a false-negative rate of 12% were recorded. Sensitivity was 88.9% (95% CI 65.3-98.6), and specificity was 95.0% (95 CI% 83.1-99. 4). Ultrasound-assisted SPA was successful in 26 of 28 patients (93%) and in 13 of 21 patients (62%) when SPA was performed without ultrasound (chi(2) = 7.08, P =.008).
We conclude that there is a good association in results of culture of urine obtained by CCU collection and SPA and would encourage the use of the CCU technique.
比较清洁中段尿(CCU)采集法与耻骨上膀胱穿刺抽吸法(SPA)获取婴儿尿液培养结果的准确性。
在一家儿科教学医院及相关新生儿病房开展的前瞻性病例系列研究。从49例疑似尿路感染的婴儿中获取了58对尿液培养样本(CCU采集样本和SPA采集样本)。主要观察指标是CCU采集样本和SPA采集样本中是否存在显著菌尿;次要观察指标是超声引导下的SPA与无超声引导下的穿刺抽吸成功率。采用卡方检验进行统计分析。
记录到假阳性率为5%,假阴性率为12%。灵敏度为88.9%(95%可信区间65.3 - 98.6),特异度为95.0%(95%可信区间83.1 - 99.4)。超声辅助下的SPA在28例患者中有26例成功(93%),无超声引导下的SPA在21例患者中有13例成功(62%)(卡方 = 7.08,P = 0.008)。
我们得出结论,CCU采集法和SPA获取的尿液培养结果之间具有良好的相关性,并且鼓励使用CCU技术。