Suppr超能文献

使用血栓靶向超声造影剂(MRX-408A1)增强血管内和左心耳血栓的可视化:体内实验性超声心动图研究。

Enhanced visualization of intravascular and left atrial appendage thrombus with the use of a thrombus-targeting ultrasonographic contrast agent (MRX-408A1): In vivo experimental echocardiographic studies.

作者信息

Takeuchi M, Ogunyankin K, Pandian N G, McCreery T P, Sweitzer R H, Caldwell V E, Unger E C, Avelar E, Sheahan M, Connolly R

机构信息

Cardiovascular Imaging and Hemodynamic Laboratory, Division of Cardiology, Tufts-New England Medical Center, Boston, MA 02111, USA.

出版信息

J Am Soc Echocardiogr. 1999 Dec;12(12):1015-21. doi: 10.1016/s0894-7317(99)70096-9.

Abstract

Echocardiographic evaluation for the recognition of intravascular and left atrial appendage thrombus remains a difficult problem. A thrombus-specific ultrasonographic contrast agent has the potential for an alternative approach for their delineation. The aim of this study was to investigate the usefulness of thrombus-specific contrast agent MRX-408A1 for the detection of acute experimentally created intravascular and intracardiac thrombus. In the first study, we created inferior vena cava thrombus in 9 dogs. With the use of fundamental 2-dimensional echocardiography imaging, we recorded images of the inferior vena cava thrombus at baseline (n = 9), with the thrombus-specific contrast agent MRX-408A1 (n = 9), and with nonspecific contrast agent MRX-113 (n = 6). In the second study, we created a left atrial appendage thrombus in 8 dogs. We imaged left atrial appendage thrombus at baseline and during MRX-113 and MRX-408A1 infusion. Thrombus was successfully created in all dogs in study 1 and in 6 of 8 dogs in study 2. MRX-408A1 produced a visually apparent increase in ultrasonographic contrast enhancement of the thrombus in all cases in which thrombus was found on autopsy. In both studies, MRX-408A1 increased the videointensity of the thrombus significantly compared with baseline images and images obtained during MRX-113 infusion. The size of the visually detectable thrombus on the image was also significantly larger during MRX-408A1 infusion than at baseline and during MRX-113 infusion. These data provide in vivo demonstration of the efficacy of a thrombus-specific contrast agent, MRX-408A1, in the detection of acute intravascular and intracardiac thrombus. It has the potential to improve the diagnostic accuracy of ultrasonography for the detection of acute thrombi at various cardiovascular sites in the clinical setting.

摘要

超声心动图评估血管内和左心耳血栓仍然是一个难题。一种血栓特异性超声造影剂可能为其鉴别提供另一种方法。本研究的目的是探讨血栓特异性造影剂MRX - 408A1在检测急性实验性形成的血管内和心内血栓中的作用。在第一项研究中,我们在9只犬中制造了下腔静脉血栓。使用二维超声心动图基础成像,我们在基线时(n = 9)、使用血栓特异性造影剂MRX - 408A1时(n = 9)以及使用非特异性造影剂MRX - 113时(n = 6)记录下腔静脉血栓的图像。在第二项研究中,我们在8只犬中制造了左心耳血栓。我们在基线时以及在输注MRX - 113和MRX - 408A1期间对左心耳血栓进行成像。在研究1中所有犬以及研究2中8只犬的6只中成功制造了血栓。在所有尸检发现血栓的病例中,MRX - 408A1使血栓的超声造影增强在视觉上明显增加。在两项研究中,与基线图像和输注MRX - 113期间获得的图像相比,MRX - 408A1显著增加了血栓的视频强度。在输注MRX - 408A1期间,图像上视觉可检测到的血栓大小也显著大于基线时和输注MRX - 113期间。这些数据提供了血栓特异性造影剂MRX - 408A1在检测急性血管内和心内血栓中的疗效的体内证据。它有可能提高超声心动图在临床环境中检测不同心血管部位急性血栓的诊断准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验