Suppr超能文献

一项关于正常人鞋内足底剪切力的研究。

A study of in-shoe plantar shear in normals.

作者信息

Hosein R, Lord M

机构信息

King's College School of Medicine and Dentistry, Bessemer Road, London, UK.

出版信息

Clin Biomech (Bristol). 2000 Jan;15(1):46-53. doi: 10.1016/s0268-0033(98)00059-x.

Abstract

OBJECTIVE

To quantify features of in-shoe plantar shear in asymptomatic adult gait.

DESIGN

In order to standardize footwear conditions and facilitate later comparison to patient groups, measurement is made in a group of adults walking freely in stock orthopaedic footwear.

BACKGROUND

Better data on plantar shear is required to complement well-documented pressure data for an overall picture of plantar stress.

METHODS

Measurements were made locally beneath the medial four metatarsal heads and heel using biaxial transducers mounted flush into an inlay. Pressure distribution was also measured.

RESULTS

The shear data revealed common features in the shear pattern occurring at defined phases of gait, with good inter-step reliability. For the five sites of interest, these values ranged from 24 kPa to 70.4 kPa, and 31 kPa to 86.5 kPa for individuals wearing nylon hose or hose-free respectively. Maximum shear occurred more laterally than maximum pressure.

CONCLUSIONS

Features of plantar shear were not always as expected; for example the forward thrust at push-off was not reflected in the anteroposterior shear stress. Because of the inter-subject variability, study of a larger group is indicated.

RELEVANCE

Mechanical stress at the plantar interface between foot and shoe is of particular clinical relevance to the formation and management of ulcers in diabetic neuropathy. It is also of relevance to shoe and orthotic design for various foot pathologies. This study provides reliable data on the shear component of plantar stress for which, unlike the well-documented pressure component, there is only sparse data so far available.

摘要

目的

量化无症状成年人步态中鞋内足底剪切力的特征。

设计

为了规范鞋类条件并便于日后与患者组进行比较,对一组穿着标准矫形鞋自由行走的成年人进行测量。

背景

需要更好的足底剪切力数据来补充记录完善的压力数据,以全面了解足底应力情况。

方法

使用 flush 安装在鞋垫中的双轴传感器在四个内侧跖骨头下方和足跟局部进行测量。还测量了压力分布。

结果

剪切力数据揭示了在特定步态阶段出现的剪切模式中的共同特征,步间可靠性良好。对于五个感兴趣的部位,穿着尼龙袜或不穿袜子的个体,这些值分别在24千帕至70.4千帕和31千帕至86.5千帕之间。最大剪切力出现的位置比最大压力更靠外侧。

结论

足底剪切力的特征并不总是如预期的那样;例如,蹬离时的向前推力并未反映在前后剪切应力中。由于个体间存在差异,表明需要研究更大的群体。

相关性

足部与鞋之间足底界面的机械应力与糖尿病神经病变中溃疡的形成和管理具有特别的临床相关性。它也与各种足部疾病的鞋类和矫形器设计相关。本研究提供了足底应力剪切分量的可靠数据,与记录完善的压力分量不同,目前关于剪切分量的数据还很稀少。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验