Schoepf U J, Helmberger T, Holzknecht N, Kang D S, Bruening R D, Aydemir S, Becker C R, Muehling O, Knez A, Haberl R, Reiser M F
Department of Clinical Radiology, Klinikum Grosshadern, University of Munich, Marchioninistr 15, 81377 Munich, Germany.
Radiology. 2000 Feb;214(2):433-9. doi: 10.1148/radiology.214.2.r00fe10433.
To compare contrast agent-enhanced spiral and electron-beam computed tomography (CT) for the analysis of segmental and subsegmental pulmonary arteries.
CT angiography of the pulmonary arteries was performed in 56 patients to rule out pulmonary embolism. Electron-beam CT was performed in 28 patients. The other 28 patients underwent spiral CT with comparable scanning protocols. The depiction of segmental and subsegmental arteries was analyzed by three independent readers. The contrast enhancement in the main pulmonary artery was measured in each patient.
Analysis was performed in 1,120 segmental and 2, 240 subsegmental arteries. One segmental (RA7, P =.010) and two subsegmental (LA7b, P =.029; RA6a+b, P =.038) arteries in paracardiac and basal segments of the lung were depicted significantly better with electron-beam CT. There was no statistically significant difference between electron-beam and spiral CT in the total number of analyzable peripheral arteries depicted. The mean contrast enhancement in the main pulmonary artery was 362 HU in electron-beam CT studies versus 248 HU in spiral CT studies.
Detailed visualization of peripheral pulmonary arteries is well within the scope of advanced CT techniques. Electron-beam CT has minor advantages in analyzing paracardiac arteries, probably because of reduction of motion artifacts and higher contrast enhancement. Further studies are needed to establish whether electron-beam CT allows a more confident diagnosis of emboli in these vessels.
比较对比剂增强螺旋CT和电子束计算机断层扫描(CT)用于分析肺段及亚段肺动脉。
对56例患者进行肺动脉CT血管造影以排除肺栓塞。28例患者接受电子束CT检查。另外28例患者采用类似扫描方案进行螺旋CT检查。由三位独立阅片者分析肺段和亚段动脉的显示情况。测量每位患者主肺动脉的对比增强情况。
对1120个肺段动脉和2240个亚段动脉进行了分析。在心旁和肺底部的一个肺段动脉(RA7,P = 0.010)和两个亚段动脉(LA7b,P = 0.029;RA6a + b,P = 0.038)在电子束CT下显示明显更好。电子束CT和螺旋CT在可分析的外周动脉总数上无统计学显著差异。电子束CT研究中主肺动脉的平均对比增强为362 HU,而螺旋CT研究中为248 HU。
外周肺动脉的详细可视化完全在先进CT技术范围内。电子束CT在分析心旁动脉方面有轻微优势,可能是由于运动伪影减少和对比增强更高。需要进一步研究以确定电子束CT是否能更可靠地诊断这些血管中的栓子。