To assess the level of awareness among UK ophthalmic surgeons of the potential risks from starch powdered surgical gloves during ophthalmic surgery and to show by electron microscopy that starch granule contamination can occur during ophthalmic surgery.
A sample (N = 46) of UK ophthalmologists from the North of England, UK.
Type of glove usage and awareness of the possible risks from starch powdered surgical gloves were assessed by means of a questionnaire sent to ophthalmic surgeons in the North of England. The surface of a polymethylmethacrylate (PMMA) intraocular lens (IOL) handled with a starch powdered surgical glove was examined by electron microscopy for evidence of starch contamination.
Of the sampled ophthalmic surgeons (46), 89.1% considered it important to use starch free surgical gloves and the 84.8% already did so. Starch granule contamination was seen by electron microscopy on the surface of a PMMA IOL which had been handled with starch powdered surgical gloves.
Although there has been sporadic attention in the ophthalmic literature to the risks associated with starch powdered surgical gloves in ophthalmology, up to 15% of UK ophthalmic surgeons may still be using starch powdered gloves. The authors show that starch powder contamination of ophthalmic materials can actually occur and remind ophthalmologists that this has been reported in the literature as a possible cause of sterile intra and extraocular inflammation.
评估英国眼科外科医生对眼科手术中淀粉粉末状手术手套潜在风险的认知水平,并通过电子显微镜证明眼科手术过程中可能发生淀粉颗粒污染。
从英国英格兰北部抽取46名眼科医生作为样本。
通过向英格兰北部的眼科外科医生发送问卷,评估手套使用类型以及对淀粉粉末状手术手套可能风险的认知。用淀粉粉末状手术手套处理过的聚甲基丙烯酸甲酯(PMMA)人工晶状体(IOL)表面,通过电子显微镜检查是否有淀粉污染的迹象。
在抽样的46名眼科外科医生中,89.1%认为使用无淀粉手术手套很重要,84.8%的医生已经这样做了。在使用淀粉粉末状手术手套处理过的PMMA IOL表面,通过电子显微镜观察到了淀粉颗粒污染。
尽管眼科文献中曾偶尔提及眼科手术中淀粉粉末状手术手套的相关风险,但仍有高达15%的英国眼科外科医生可能在使用淀粉粉末状手套。作者表明,眼科材料的淀粉粉末污染确实可能发生,并提醒眼科医生,文献中已报道这可能是眼内和眼外无菌性炎症的一个原因。