Rogers G F, Sargent L A
Department of Plastic Surgery, University of Tennessee College of Medicine, Chattanooga 37403, USA.
Plast Reconstr Surg. 2000 Feb;105(2):695-7. doi: 10.1097/00006534-200002000-00033.
We report a technique that uses a modified standard towel clamp, allowing a single surgeon to perform and maintain an anatomic reduction of displaced mandible fractures simultaneous with the application of internal fixation. The reduced convergent angle of the modified towel clamp allows bicortical engagement of the clamp, which prevents comminution of the fracture or the outer cortex of the mandible. Additionally, the modification allows the clamp to engage the bone with less exposure than conventional towel clamps. In our clinical experience of treating more than 100 mandible fractures a year, this technique proves superior to others described in the literature.
我们报告了一种使用改良标准巾钳的技术,该技术使单一外科医生能够在应用内固定的同时对移位的下颌骨骨折进行并维持解剖复位。改良巾钳减小的收敛角度允许其双侧皮质骨啮合,从而防止骨折或下颌骨外皮质粉碎。此外,这种改良使巾钳在比传统巾钳暴露更少的情况下与骨接合。在我们每年治疗100多例下颌骨骨折的临床经验中,该技术证明优于文献中描述的其他技术。