Suppr超能文献

近似熵作为地氟醚麻醉期间麻醉药物效应的脑电图测量指标。

Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia.

作者信息

Bruhn J, Röpcke H, Hoeft A

机构信息

Department of Anesthesiology and Intensive Care Medicine, University of Bonn, Germany.

出版信息

Anesthesiology. 2000 Mar;92(3):715-26. doi: 10.1097/00000542-200003000-00016.

Abstract

BACKGROUND

The authors hypothesized that the electroencephalogram (EEG) during higher anesthetic concentrations would show more "order" and less "randomness" than at lower anesthetic concentrations. "Approximate entropy" is a new statistical parameter derived from the Kolmogorov-Sinai entropy formula which quantifies the amount of regularity in data. The approximate entropy quantifies the predictability of subsequent amplitude values of the EEG based on the knowledge of the previous amplitude values. The authors investigated the dose-response relation of the EEG approximate entropy during desflurane anesthesia in comparison with spectral edge frequency 95, median frequency, and bispectral index.

METHODS

Twelve female patients were studied during gynecologic laparotomies. Between opening and closure of the peritoneum, end-tidal desflurane concentrations were varied between 0.5 and 1.6 minimum alveolar concentration (MAC). The EEG approximate entropy, median EEG frequency, spectral edge frequency 95, and bispectral index were determined and the performance of each to predict the desflurane effect compartment concentration, obtained by simultaneous pharmacokinetic-pharmacodynamic modeling, was compared.

RESULTS

Electroencephalogram approximate entropy decreased continuously over the observed concentration range of desflurane. The performance of the approximate entropy (prediction probability PK = 0.86 +/- 0.06) as an indicator for desflurane concentrations is similar to spectral edge frequency 95 (PK = 0.86 +/- 0.06) and bispectral index (PK = 0.82 +/- 0.06) and is statistically significantly better than median frequency (PK = 0.78 +/- 0.06).

CONCLUSIONS

The amount of regularity in the EEG increases with increasing desflurane concentrations. The approximate entropy could be a useful EEG measure of anesthetic drug effect.

摘要

背景

作者推测,与较低麻醉浓度时相比,较高麻醉浓度下的脑电图(EEG)将显示出更多的“有序性”和更少的“随机性”。“近似熵”是一种从Kolmogorov-Sinai熵公式推导而来的新统计参数,用于量化数据中的规律性程度。近似熵基于先前振幅值的知识来量化EEG后续振幅值的可预测性。作者研究了地氟烷麻醉期间EEG近似熵与频谱边缘频率95、中位频率和脑电双频指数的剂量反应关系。

方法

对12例接受妇科剖腹手术的女性患者进行研究。在腹膜打开和关闭之间,呼气末地氟烷浓度在0.5至1.6最低肺泡浓度(MAC)之间变化。测定EEG近似熵、EEG中位频率、频谱边缘频率95和脑电双频指数,并比较通过同时进行药代动力学-药效学建模获得的各指标预测地氟烷效应室浓度的性能。

结果

在地氟烷观察到的浓度范围内,脑电图近似熵持续下降。近似熵作为地氟烷浓度指标的性能(预测概率PK = 0.86±0.06)与频谱边缘频率95(PK = 0.86±0.06)和脑电双频指数(PK = 0.82±0.06)相似,且在统计学上显著优于中位频率(PK = 0.78±0.06)。

结论

随着地氟烷浓度的增加,脑电图中的规律性程度增加。近似熵可能是一种有用的衡量麻醉药物效应的脑电图指标。