颈椎活动度测量工具已发表可靠性研究的评估。

Assessment of published reliability studies for cervical spine range-of-motion measurement tools.

作者信息

Jordan K

机构信息

Research Fellow, Centre for Health Planning and Management and Department of Mathematics, Keele University, United Kingdom.

出版信息

J Manipulative Physiol Ther. 2000 Mar-Apr;23(3):180-95. doi: 10.1016/s0161-4754(00)90248-3.

Abstract

OBJECTIVE

To assess the reliability of tools to measure cervical spine range of motion in clinical settings and discuss the necessary components for reliability studies.

DATA SOURCES

Database searches included Bandolier, Bath Information and Data Services including Index of Scientific and Technical Proceedings, British Nursing Index, Cumulative Index to Nursing and Allied Health Literature, English National Health Care Database, MEDLINE, Occupational Therapy Index, Physiotherapy Index, and Rehabilitation index for English language articles from 1966. In addition, citations were searched.

STUDY SELECTION

Studies were selected that assessed the tool for intraobserver or interobserver reliability, evaluated it on movements of flexion/extension, lateral flexion, or rotation, and measured range of motion of the whole cervical spine.

DATA EXTRACTION

All papers were read by one nonclinical researcher with a data extraction sheet. A consultant rheumatologist and a physiotherapist were each asked to read a sample of the papers to give a clinical viewpoint.

DATA SYNTHESIS

Evidence for the reliability of measurement tools was assessed qualitatively based on the quality of the study designs, appropriateness of analysis, and strength of the reliability based on reported intraclass correlation coefficients (the most appropriate analysis technique for reliability studies of this nature). Measurement tools were found to have not been fully tested for reliability, particularly in terms of adequate sample size and appropriate analysis techniques. There were also wide variations in the research design, including the protocol for movement, the characteristics of observers and study population, whether warm-ups were allowed, whether the movement was active or passive, and time intervals between repeated measurements.

CONCLUSION

Although a range-of-motion device has shown promise in reliability and has many advocates, its practicality for clinical use is questionable. Further work must be performed on all measurement tools. Researchers need to produce more rigorous studies and consider the issues discussed here.

摘要

目的

评估在临床环境中测量颈椎活动范围的工具的可靠性,并讨论可靠性研究的必要组成部分。

数据来源

数据库检索包括Bandolier、巴斯信息与数据服务(包括科技会议录索引、英国护理索引、护理及相关健康文献累积索引、英国国家医疗保健数据库、医学索引数据库、职业治疗索引、物理治疗索引以及1966年以来的英文康复索引)。此外,还进行了引文检索。

研究选择

选取评估工具观察者内或观察者间可靠性、在屈伸、侧屈或旋转运动方面进行评估且测量整个颈椎活动范围的研究。

数据提取

一位非临床研究人员使用数据提取表阅读所有论文。分别邀请一位风湿科顾问医生和一位物理治疗师阅读部分论文样本以提供临床观点。

数据综合

基于研究设计质量、分析的适当性以及根据报告的组内相关系数得出的可靠性强度(此类可靠性研究最合适的分析技术),对测量工具可靠性的证据进行定性评估。发现测量工具的可靠性尚未得到充分测试,特别是在样本量充足和分析技术适当方面。研究设计也存在很大差异,包括运动方案、观察者和研究人群的特征、是否允许热身、运动是主动还是被动以及重复测量之间的时间间隔。

结论

尽管一种活动范围测量装置在可靠性方面已显示出前景且有许多支持者,但其临床实用性值得怀疑。必须对所有测量工具开展进一步研究。研究人员需要进行更严谨的研究并考虑此处讨论的问题。