Alexandridis E, Ariely E, Gronau G
Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1975;194(4 Suppl):237-41. doi: 10.1007/BF00414670.
The influence of globe prominence on the electro-oculogram potential level was measured in patients with unilateral protrusio bulbi, myopia or hyperopia. The EOG potential level on the side with the more prominent globe was lower if the prominence was due to protrusion. If the prominence was due to myopia, the EOG potential was higher compared to the contralateral non-myopic eye. In hyperopic eyes the potential level was lower.