Hardarson T, Lundin K, Hamberger L
Department of Obstetrics and Gynaecology, Göteborg University, Sweden.
Hum Reprod. 2000 Jun;15(6):1372-6. doi: 10.1093/humrep/15.6.1372.
When performing intracytoplasmic sperm injection (ICSI) on human oocytes, the injection is traditionally made at the 3 o'clock position, with the first polar body (PB) at the 12 or 6 o'clock position. This has been based on the assumption that the second meiotic metaphase II (MII) spindle lies in close proximity to the first PB. The objective of this study was to document the actual spatial relationship between the first PB and the MII spindle both in in-vivo matured (fresh) human MII oocytes and in oocytes matured in vitro. We found that the MII spindle was, on average, not located directly adjacent to the PB. The in-vivo group (n = 54) showed a mean deviation of the MII spindle from the position of the PB of 41. 7 degrees and the in-vitro group 26.6 degrees (n = 43). The difference between the angle of the two groups was statistically significant (P = 0.005), indicating that the lateral displacement of the first PB is only partly due to the denuding procedure during ICSI, because the in-vitro matured oocytes were denuded before extrusion of the first PB. The majority of the MII spindles in both groups were found in the same hemisphere as the first PB, suggesting that care should be taken to avoid damaging the MII spindle by inserting the ICSI needle in the other half of the oocyte.
在对人类卵母细胞进行胞浆内单精子注射(ICSI)时,传统上是在3点位置进行注射,第一极体(PB)位于12点或6点位置。这是基于第二减数分裂中期II(MII)纺锤体紧邻第一极体的假设。本研究的目的是记录在体内成熟(新鲜)的人类MII卵母细胞和体外成熟的卵母细胞中,第一极体与MII纺锤体之间的实际空间关系。我们发现,MII纺锤体平均而言并非直接紧邻极体。体内组(n = 54)显示MII纺锤体与极体位置的平均偏差为41.7度,体外组为26.6度(n = 43)。两组角度之间的差异具有统计学意义(P = 0.0),表明第一极体的侧向位移仅部分归因于ICSI过程中的去卵丘操作,因为体外成熟的卵母细胞在挤出第一极体之前就已去除卵丘。两组中大多数MII纺锤体都位于与第一极体相同的半球,这表明在卵母细胞的另一半插入ICSI针时应小心避免损伤MII纺锤体。