Erceg M, Maricević A
Department of Orthopedics, Split University Hospital, Split, Croatia.
Croat Med J. 2000 Jun;41(2):207-9.
In our series of 136 patients with primary total knee arthroplasty using posterior-stabilized prosthesis, a female patient with Parkinson disease developed posterior dislocation of the knee 9 months after surgery. Eventually, the dislocation became recurrent, occurring several times a day. The patient made the reposition always by herself. Two months after the first dislocation, we performed the revision of the polyethylene tibial insert and found wearing of the tibial insert's cam as an hitherto unreported cause of the mechanical instability of the total knee prosthesis.
在我们使用后稳定型假体进行初次全膝关节置换的136例患者系列中,一名患有帕金森病的女性患者在术后9个月出现膝关节后脱位。最终,脱位反复发作,每天发生数次。患者总是自行复位。首次脱位两个月后,我们对聚乙烯胫骨衬垫进行了翻修,发现胫骨衬垫凸轮磨损是全膝关节假体机械不稳定的一个此前未报告的原因。