Sin S W, Chow D H, Cheng J C
Prosthetic and Orthotic Department, Prince of Wales Hospital, Hong Kong SAR.
Prosthet Orthot Int. 1999 Dec;23(3):225-30. doi: 10.3109/03093649909071638.
Clinically, it is hard to achieve and reproduce prosthesis alignment at will during daily prosthesis fitting. A new alignment jig was designed and developed to facilitate quantification and prescription of prosthesis alignment for patellar-tendon-bearing (PTB) trans-tibial prostheses. The alignment jig provided instantaneous readings of the three-dimensional orientation and position of the socket relative to the prosthetic foot in standardised units. The inter- and intra-tester errors of the alignment jig in measuring prosthesis alignment were evaluated and demonstrated to have good reliability. The alignment jig was recommended to be used clinically after the conventional dynamic alignment procedure to document the prosthesis alignment. Further application of the alignment jig for systematic evaluation of the effects of prosthesis alignment on gait for trans-tibial amputees is suggested.
临床上,在日常假肢装配过程中,很难随意实现并重现假肢对线。设计并开发了一种新的对线夹具,以促进髌韧带承重(PTB)经胫假肢对线的量化和处方制定。该对线夹具以标准化单位提供了接受腔相对于假肢足部的三维方向和位置的即时读数。评估了对线夹具在测量假肢对线时的测试者间和测试者内误差,并证明其具有良好的可靠性。建议在传统动态对线程序后临床上使用该对线夹具记录假肢对线情况。还建议进一步应用该对线夹具系统评估假肢对线对经胫截肢者步态的影响。