Suppr超能文献

Is there a risk of cross-infection from laundered reusable bedpads?

作者信息

Cottenden A M, Moore K N, Fader M J, Cremer A W

机构信息

Department of Medical Physics and Bioengineering, University College London.

出版信息

Br J Nurs. 1999;8(17):1161-3. doi: 10.12968/bjon.1999.8.17.6492.

Abstract

The risk of cross-infection from reusable incontinence bedpads was assessed by determining their microbial content after one night's use by incontinent adults and after laundering using the standard foul wash procedure specified by the NHS Executive (NHS E, 1995) (which includes heat disinfection at 71 degrees C for 3 minutes). Measurements were made on a total of 145 bedpads from five different product designs. It was found that effective laundering destroyed all known pathogenic organisms, although some commensal flora were isolated in small numbers (mean 12.2 colony forming units/ml). It is concluded that laundering reusable incontinence pads using the foul wash procedure leaves pads safe for multiple patient reuse with no demonstrable risk of cross-infection.

摘要

相似文献

1
Is there a risk of cross-infection from laundered reusable bedpads?
Br J Nurs. 1999;8(17):1161-3. doi: 10.12968/bjon.1999.8.17.6492.
10
Contamination of hospital linen by Bacillus cereus.蜡样芽孢杆菌对医院织物的污染。
Epidemiol Infect. 1994 Oct;113(2):297-306. doi: 10.1017/s0950268800051724.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验