Poiger T, Richardson S D, Baughman G L
Ecosystems Research Division, National Exposure Research Laboratory, US Environmental Protection Agency, Athens, GA 30605, USA.
J Chromatogr A. 2000 Jul 21;886(1-2):259-70. doi: 10.1016/s0021-9673(00)00483-0.
Capillary electrophoresis-mass spectrometry was applied to the separation of several anionic dyes containing copper(II), chromium(III), or cobalt(III) as part of the dye molecule. The dyes were separated using a 110 cm x 50 microm uncoated fused-silica capillary and a 5 mM ammonium acetate buffer (pH 9) containing 40% acetonitrile. Excellent separation efficiencies (N = 500,000 plates/column) and low detection limits of 20-50 pg (selected ion monitoring, S/N = 10) were achieved. Mass spectra were acquired at different cone voltages. At low cone voltages (low collision energies), sensitivity was maximized and the mass spectra contained only signals of the (multiply charged) molecular ions and low levels of sodium ion and proton adducts. At higher cone voltages, the 2:1 (ligand:metal) chromium and cobalt dyes showed losses of one of the two dye ligands, accompanied by a reduction of the metal. The copper dyes showed signals due to loss of SO2 and SO3-, but no release of metal. Azo cleavage, otherwise typical of azo dyes, was not observed with the metallized dyes.