The induction of dicentric chromosomes in human lymphocytes from one individual irradiated in vitro with monoenergetic neutrons at 565 keV was examined to provide additional data for an improved evaluation of neutrons with respect to radiation risk in radioprotection. The resulting linear dose-response relationship obtained (0.813 +/- 0.052 dicentrics per cell per gray) over the dose range of 0.0213-0.167 Gy is consistent with published results obtained for irradiation with neutrons from different sources and with different spectra at energies lower than 1000 keV. Comparing this value to previously published "average" dose-response curves obtained by different laboratories for (60)Co gamma rays and orthovoltage X rays resulted in maximum RBEs (RBE(m)) of about 37 +/- 8 and 16 +/- 4, respectively. However, when our neutron data were matched to low-LET dose responses that were constructed several years earlier for lymphocytes from the same individual, higher values of RBE(m) resulted: 76.0 +/- 29.5 for (60)Co gamma rays and 54.2 +/- 18.4 for (137)Cs gamma rays; differentially filtered 220 kV X rays produced values of RBE(m) between 20.3 +/- 2.0 or 37.0 +/- 7. 1. The results highlight the dependence of RBE(m) on the choice of low-LET reference radiation and raise the possibility that differential individual response to low-LET radiations may need to be examined more fully in this context.
对一名个体的人淋巴细胞进行体外565 keV单能中子照射,检测双着丝粒染色体的诱导情况,以便为改进中子在辐射防护中辐射风险评估提供更多数据。在0.0213 - 0.167 Gy剂量范围内获得的线性剂量反应关系(每细胞每格雷0.813±0.052个双着丝粒)与已发表的关于能量低于1000 keV的不同来源和不同能谱的中子照射结果一致。将该值与不同实验室先前发表的关于(60)Coγ射线和深部X射线的“平均”剂量反应曲线进行比较,得到的最大相对生物效应(RBE(m))分别约为37±8和16±4。然而,当将我们的中子数据与几年前为同一人淋巴细胞构建的低线性能量传递剂量反应相匹配时,得到了更高的RBE(m)值:(60)Coγ射线为76.0±29.5,(137)Csγ射线为54.2±18.4;经过不同过滤的220 kV X射线产生的RBE(m)值在20.3±2.0或37.0±7.1之间。结果突出了RBE(m)对低线性能量传递参考辐射选择的依赖性,并增加了在这种情况下可能需要更全面地研究对低线性能量传递辐射的个体差异反应的可能性。