Suppr超能文献

采用(99m)锝-六甲丙二胺肟单光子发射计算机断层扫描和单点静脉血采样进行脑血流的无创测量。

Noninvasive measurement of cerebral blood flow with (99m)Tc-hexamethylpropyleneamine oxime single-photon emission computed tomography and 1-point venous blood sampling.

作者信息

Isaka Y, Furukawa S, Etani H, Nakanishi E, Ooe Y, Imaizumi M

机构信息

Department of Internal Medicine, Osaka National Hospital, Osaka, Japan.

出版信息

Stroke. 2000 Sep;31(9):2203-7. doi: 10.1161/01.str.31.9.2203.

Abstract

BACKGROUND AND PURPOSE

The arterial and venous blood concentration of technetium 99m-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) reaches an equilibration more rapidly than other CBF tracers. We hypothesized that (99m)Tc radioactivity of a venous sample at equilibrium, which is similar to that of an arterial sample, would allow estimation of the integrated input function for the clinical measurement of CBF by use of single-photon emission CT.

METHODS

In 53 patients with stable cerebrovascular disease, the radioactivity of a venous sample 5 minutes after injection of (99m)Tc-HMPAO was correlated with 5-minute arterial blood radioactivity and the first 5 minutes of the integrated arterial curves of the lipophilic tracer. The measured CBF values were compared with those of xenon 133.

RESULTS

The radioactivity of 5-minute venous blood was almost equivalent to that of 5-minute arterial blood (r(2) = 0.987; y = 0.993x + 1.63; P : <0.0001). The correlation between the venous blood radioactivity and the integrated arterial lipophilic fraction was excellent (r(2) = 0.935, P : <0.0001). A strong correlation was obtained between (99m)Tc-HMPAO and (133)Xe CBF values (r(2) = 0.825, P : <0.0001). CBF values were reproducible (coefficient of variation, 8.6%).

CONCLUSIONS

This approach is fast, simple, and an alternative to continuous blood sampling in clinical quantitative (99m)Tc-HMPAO CBF studies.

摘要

背景与目的

与其他脑血流量(CBF)示踪剂相比,99m锝标记的六甲基丙烯胺肟((99m)Tc-HMPAO)在动脉血和静脉血中的浓度达到平衡的速度更快。我们推测,平衡时静脉样本的(99m)Tc放射性与动脉样本相似,这将有助于通过单光子发射计算机断层扫描(SPECT)对临床CBF测量中积分输入函数进行估计。

方法

对53例患有稳定脑血管疾病的患者,在注射(99m)Tc-HMPAO后5分钟,静脉样本的放射性与5分钟动脉血放射性以及亲脂性示踪剂的动脉积分曲线的前5分钟进行相关性分析。将测量得到的CBF值与133氙的CBF值进行比较。

结果

5分钟静脉血的放射性几乎与5分钟动脉血的放射性相当(r² = 0.987;y = 0.993x + 1.63;P < 0.0001)。静脉血放射性与动脉亲脂部分的积分之间具有良好的相关性(r² = 0.935,P < 0.0001)。(99m)Tc-HMPAO与(133)Xe的CBF值之间存在强相关性(r² = 0.825,P < 0.0001)。CBF值具有可重复性(变异系数为8.6%)。

结论

在临床定量(99m)Tc-HMPAO CBF研究中,这种方法快速、简单,是连续采血的一种替代方法。