Jenkins D M, Delwiche M J, DePeters E J, BonDurant R H
Department of Biological and Agricultural Engineering, University of California at Davis, 95616, USA.
J Dairy Sci. 2000 Sep;83(9):2042-8. doi: 10.3168/jds.S0022-0302(00)75085-5.
We report improvements in the application of a pressure-based assay for urea. The assay involved the enzymatic hydrolysis of urea and subsequent measurement of CO2 partial pressure. Effects of the preservative bronopol on the assay and their implications for laboratory applications are discussed. A method of remediating these effects with cysteine is described. A method is also described wherein these additives can be used to prepare standards of known urea concentration in milk. The improved assay can be used to measure urea N in unadulterated milk or in bronopol preserved milk with an accuracy of +/-0.7 mg/dl (0.25 mM) in the range from 0 to 30 mg/dl (0 to 10.7 mM).
我们报告了基于压力的尿素检测方法应用方面的改进。该检测方法涉及尿素的酶促水解以及随后二氧化碳分压的测量。讨论了防腐剂溴硝醇对该检测方法的影响及其在实验室应用中的意义。描述了一种用半胱氨酸补救这些影响的方法。还描述了一种方法,其中这些添加剂可用于制备牛奶中已知尿素浓度的标准品。改进后的检测方法可用于测量未掺假牛奶或用溴硝醇保存的牛奶中的尿素氮,在0至30毫克/分升(0至10.7毫摩尔)范围内的准确度为±0.7毫克/分升(0.25毫摩尔)。