Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

作者信息

Stenger V A, Boada F E, Noll D C

机构信息

Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

出版信息

Magn Reson Med. 2000 Oct;44(4):525-31. doi: 10.1002/1522-2594(200010)44:4<525::aid-mrm5>3.0.co;2-l.

Abstract

A three-dimensional tailored RF pulse method for reducing intravoxel dephasing artifacts in T *(2)-weighted functional MRI is presented. A stack of spirals k-space trajectory is employed to excite a disk of magnetization for small tip angles. Smaller disks with a linear through-plane phase are inserted into the disk to locally refocus regions which are normally dephased due to susceptibility variations. Numerical simulations and imaging experiments which use the tailored RF pulses are presented. Limitations of the method and improvements are also discussed.

摘要

相似文献

1
Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.
Magn Reson Med. 2000 Oct;44(4):525-31. doi: 10.1002/1522-2594(200010)44:4<525::aid-mrm5>3.0.co;2-l.
2
Variable-density spiral 3D tailored RF pulses.
Magn Reson Med. 2003 Nov;50(5):1100-6. doi: 10.1002/mrm.10623.
3
Multishot 3D slice-select tailored RF pulses for MRI.
Magn Reson Med. 2002 Jul;48(1):157-65. doi: 10.1002/mrm.10194.
7
Optimized ultra-fast imaging sequence (OUFIS).
Magn Reson Med. 1995 Mar;33(3):377-95. doi: 10.1002/mrm.1910330311.
8
A novel flow-suppression technique using tailored RF pulses.
Magn Reson Med. 1993 May;29(5):660-6. doi: 10.1002/mrm.1910290513.
9
Strategies for improved 3D small-tip fast recovery imaging.
Magn Reson Med. 2014 Aug;72(2):389-98. doi: 10.1002/mrm.24947. Epub 2013 Oct 11.
10
Composite pulses for RF phase encoded MRI: A simulation study.
Magn Reson Imaging. 2017 Feb;36:40-48. doi: 10.1016/j.mri.2016.10.007. Epub 2016 Oct 12.

引用本文的文献

1
A single oscillating waveform-based gradient delay estimation.
Magn Reson Imaging. 2025 Jun;119:110367. doi: 10.1016/j.mri.2025.110367. Epub 2025 Mar 4.
3
Prediction of motion induced magnetic fields for human brain MRI at 3 T.
MAGMA. 2023 Oct;36(5):797-813. doi: 10.1007/s10334-023-01076-0. Epub 2023 Mar 25.
5
k-Space Domain Parallel Transmit Pulse Design.
Magn Reson Med. 2021 May;85(5):2568-2579. doi: 10.1002/mrm.28601. Epub 2020 Nov 26.
6
Improved PRF-based MR thermometry using k-space energy spectrum analysis.
Magn Reson Med. 2020 Dec;84(6):3325-3332. doi: 10.1002/mrm.28341. Epub 2020 Jun 25.
7
Imaging Cerebral Activity in Amyotrophic Lateral Sclerosis.
Front Neurol. 2019 Jan 8;9:1148. doi: 10.3389/fneur.2018.01148. eCollection 2018.
8
Computational and experimental evaluation of the Tic-Tac-Toe RF coil for 7 Tesla MRI.
PLoS One. 2019 Jan 10;14(1):e0209663. doi: 10.1371/journal.pone.0209663. eCollection 2019.
9
Maximising BOLD sensitivity through automated EPI protocol optimisation.
Neuroimage. 2019 Apr 1;189:159-170. doi: 10.1016/j.neuroimage.2018.12.052. Epub 2018 Dec 26.
10
Effects of acute Δ9-tetrahydrocannabinol on next-day extinction recall is mediated by post-extinction resting-state brain dynamics.
Neuropharmacology. 2018 Dec;143:289-298. doi: 10.1016/j.neuropharm.2018.10.002. Epub 2018 Oct 3.

本文引用的文献

1
A k-space analysis of small-tip-angle excitation. 1989.
J Magn Reson. 2011 Dec;213(2):544-57. doi: 10.1016/j.jmr.2011.09.023.
2
Spiral sampling in magnetic resonance imaging-the effect of inhomogeneities.
IEEE Trans Med Imaging. 1987;6(4):337-45. doi: 10.1109/TMI.1987.4307852.
3
High-speed spiral-scan echo planar NMR imaging-I.
IEEE Trans Med Imaging. 1986;5(1):2-7. doi: 10.1109/TMI.1986.4307732.
4
A homogeneity correction method for magnetic resonance imaging with time-varying gradients.
IEEE Trans Med Imaging. 1991;10(4):629-37. doi: 10.1109/42.108599.
5
Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique.
Magn Reson Med. 1999 Oct;42(4):807-12. doi: 10.1002/(sici)1522-2594(199910)42:4<807::aid-mrm25>3.0.co;2-8.
6
Simple analytic spiral K-space algorithm.
Magn Reson Med. 1999 Aug;42(2):412-5. doi: 10.1002/(sici)1522-2594(199908)42:2<412::aid-mrm25>3.0.co;2-u.
7
3D z-shim method for reduction of susceptibility effects in BOLD fMRI.
Magn Reson Med. 1999 Aug;42(2):290-9. doi: 10.1002/(sici)1522-2594(199908)42:2<290::aid-mrm11>3.0.co;2-n.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验