Shellock F G, Shields C L
University of Southern California, School of Medicine, Los Angeles,USA.
Am J Sports Med. 2000 Sep-Oct;28(5):720-4. doi: 10.1177/03635465000280051701.
Radiofrequency energy is used for thermal-assisted chondroplasty to treat grade II and III chondromalacia with the lowest possible energy setting that achieves the desired result. The purpose of this in vitro study was to determine the temperature changes associated with the use of radiofrequency energy delivered at different settings to bovine articular cartilage using a bipolar electrode. Cartilage samples were placed in a temperature-controlled (37 degrees C) saline bath for the delivery of radiofrequency energy. A fluoroptic thermometry probe was positioned to record the temperatures at the electrode-tissue interface. The electrode was activated for 2 seconds at settings of V2-120, V2-60, V2-40, and V2-20 in two modes: ablation and desiccation. Additionally, the cartilage samples were visually inspected to determine changes in appearance. The highest average temperatures were as follows: ablation mode, 78.5 degrees C (V2-120), 62.6 degrees C (V2-60), 58.1 degrees C (V2-40), and 54.1 degrees C (V2-20); desiccation mode, 71.8 degrees C (V2-120), 61.4 degrees C (V2-60), 57.7 degrees C (V2-40), and 53.3 degrees C (V2-20). There were statistically significant increases in temperatures associated with each of the respective settings. There were no substantial visual changes produced by the V2-20 settings, while the other settings produced a gradation of effects. These data provide information to help guide the use of a bipolar radiofrequency electrode and electrosurgical system for thermal-assisted chondroplasty.
射频能量用于热辅助软骨成形术,以尽可能低的能量设置治疗II级和III级软骨软化症,并达到预期效果。本体外研究的目的是确定使用双极电极在不同设置下向牛关节软骨输送射频能量时的温度变化。将软骨样本置于温度控制为37摄氏度的盐水中,以输送射频能量。放置一个荧光温度测量探头来记录电极与组织界面处的温度。电极在V2 - 120、V2 - 60、V2 - 40和V2 - 20的设置下以两种模式激活2秒:消融和干燥。此外,对软骨样本进行视觉检查以确定外观变化。最高平均温度如下:消融模式下,分别为78.5摄氏度(V2 - 120)、62.6摄氏度(V2 - 60)、58.1摄氏度(V2 - 40)和54.1摄氏度(V2 - 20);干燥模式下,分别为71.8摄氏度(V2 - 120)、61.4摄氏度(V2 - 60)、57.7摄氏度(V2 - 40)和53.3摄氏度(V2 - 20)。与各个设置相关的温度有统计学上的显著升高。V2 - 20设置未产生明显的视觉变化,而其他设置产生了不同程度的效果。这些数据为指导双极射频电极和电外科系统在热辅助软骨成形术中的使用提供了信息。