Suppr超能文献

Hypertrophic obstructive cardiomyopathy. Assessment by echocardiographic and Doppler ultrasound techniques.

作者信息

Boughner D R, Schuld R L, Persaud J A

出版信息

Br Heart J. 1975 Sep;37(9):917-23. doi: 10.1136/hrt.37.9.917.

Abstract

Hypertrophic obstructive cardiomyopathy is a disease of the myocardium that can be assessed echocardiographic and transcutaneous Doppler ultrasound techniques. Four patients are presented with various patterns of the disease, and the frequently familial incidence is illustrated. The importance of ultrasonic evidence for asymmetric septal hypertrophy in all stages is emphasized and evidence of reduced septal contractility demonstrated. Abnormalities of mitral valve motion, slow diastolic closure rate and systolic anterior movement of the anterior leaflet, are shown in the obstructive form of the disease. Also partial mid-systolic aortic valve closure and aortic cusp flutter are shown with outflow obstruction. The outflow tract gradient can be calculated from mitral valve to septum systolic distances. Transcutaneous Doppler ultrasound shows a normal aortic velocity pattern in nonobstructive disease while consistent abnormalities are present with severe resting obstruction. Isoprenaline can be used to alter the normal velocity pattern associated with a minimal resting gradient to an abnormal pattern indicating the development of significant obstruction.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8c39/482898/ac2f62ee8b03/brheartj00259-0026-a.jpg

相似文献

2
Dynamic subaortic obstruction in hypertrophic cardiomyopathy: analysis by pulsed Doppler echocardiography.
J Am Coll Cardiol. 1985 Jul;6(1):1-18. doi: 10.1016/s0735-1097(85)80244-8.
4
Mitral stenosis and hypertrophic obstructive cardiomyopathy: An unusual combination.
J Thorac Cardiovasc Surg. 2016 Apr;151(4):1044-8. doi: 10.1016/j.jtcvs.2015.11.048. Epub 2015 Dec 8.
8
Patterns and timing of Doppler-detected intracavitary and aortic flow in hypertrophic cardiomyopathy.
J Am Coll Cardiol. 1986 Nov;8(5):1047-58. doi: 10.1016/s0735-1097(86)80381-3.
9
Echocardiographic spectrum of hypertrophic cardiomyopathy.
Br Heart J. 1975 Dec;37(12):1286-302. doi: 10.1136/hrt.37.12.1286.

本文引用的文献

1
PRESSURE-FLOW STUDIES IN HYPERTROPHIC SUBAORTIC STENOSIS.
J Clin Invest. 1964 Mar;43(3):401-7. doi: 10.1172/JCI104924.
2
Idiopathic ventricular septal hypertrophy causing muscular subaortic stenosis.
Circulation. 1962 Sep;26:325-40. doi: 10.1161/01.cir.26.3.325.
3
Non-injurious ultrasonic technique for observing flow in the human aorta.
Nature. 1969 Dec 13;224(5224):1119-21. doi: 10.1038/2241119a0.
5
Diagnosis of hypertrophic subaortic stenosis with a Doppler velocity flow detector.
Ann Intern Med. 1971 May;74(5):692-6. doi: 10.7326/0003-4819-74-5-692.
6
Echocardiographic findings in discrete subvalvular aortic stenosis.
Circulation. 1974 Feb;49(2):226-31. doi: 10.1161/01.cir.49.2.226.
7
Familial prevalence and genetic transmission of idiopathic hypertrophic subaortic stenosis.
N Engl J Med. 1973 Oct 4;289(14):709-14. doi: 10.1056/NEJM197310042891402.
10
Clinical applications of echocardiography.
Prog Cardiovasc Dis. 1972 May;14(6):531-58. doi: 10.1016/0033-0620(72)90007-2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验