Suppr超能文献

[The Balser plate with ligament suture. A dependable method of stabilizing the acromioclavicular joint].

作者信息

Folwaczny E K, Yakisan D, Stürmer K M

机构信息

Klinik für Unfallchirurgie, Plastische und Wiederherstellungschirurgie, Universitätsklinikum, Georg-August-Universität, Göttingen.

出版信息

Unfallchirurg. 2000 Sep;103(9):731-40. doi: 10.1007/s001130050612.

Abstract

Between June 1990 and December 1997 116 patients with complete dislocation of the acromio-clavicular joint were treated operatively. According to the classification of Tossy and Rockwood all patients had type Tossy III or Rockwood III, IV and V of lesion. The retrospective part of the study from June 1990 to August 1994 represents 48 patients treated in 31 cases with wire-cerclage, in 14 cases with PDS-cerclage and in 3 cases with a combination of Kirschner wires and PDS. In a second group between September 1994 and 1997 68 patients were treated operatively with a special hook-plate, called Balser-plate, combined with suture of the corakoclavicular ligaments, the articular capsule and the intraarticular discuss. In the first group there was a postoperative immobilisation of the injured shoulder for 2,3 weeks necessary; in comparison to non immobilisation at the Balser-plate group. The range of motion in the Balser-plate group was free up to 90 degrees abduction. The removal of implants was performed in both groups after approximately 3 month. Postoperative complications were 8 reluxations at the acromio-clavicular joint and 10 superficial infects at the Non-Balser group and 4 superficial infects and 2 subcutaneous haematoma in the Balser group. We saw no reluxation in the Balser group. We examined 30 of 48 patients of the Non Balser group after average 50.1 month and 57 of 68 patients of the Balser group after 24.6 month. We compared the functional result, a questionnaire and the ultrasound examination of the acromio-clavicular joint with and without 10 kg weight bearing of the arm. 87.7% of the Balser patients and 67.7% of the Non-Balser-patients had free movement of the injured shoulder. Another 14.2% and 11.4% of the Balser group complained on shoulder pain with weight bearing and extreme moval in comparison to 17.4% of the Non-Balser group. At ultrasound examination comparing the injured to the non injured arm with and without 10 kg weight bearing there was a clavicula-elevation of 0.3 mm and 0.6 mm at Balser-patients and 3.0 mm and 2.5 mm at Non-Balser-patients for the injured side. In normal position the acromio-clavicular width was physiological in 50.2% of Balser patients in comparison to 36.6% of Non-Balser-patients. Under weight bearing the acromio-clavicular width increases in both groups. 63.2% of the Balser-group patients are satisfied with the result of operation, but only 43.3% of the other group (p < 0.05). Completely dissatisfied were 20% of the Non-Balser group, particularly because of the bad cosmetic result (40%).

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验