Somia N N, Rash G S, Epstein E E, Wachowiak M, Sundine M J, Stremel R W, Barker J H, Gossman D
Division of Plastic and Reconstructive Surgery, Department of Surgery, University of Louisville, 320 MDR Building, Louisville, KY 40292, USA.
Clin Biomech (Bristol). 2000 Dec;15(10):766-71. doi: 10.1016/s0268-0033(00)00062-0.
To demonstrate how computerized eyelid motion analysis can quantify the human reflex blink.
Seventeen normal subjects and 10 patients with unilateral facial nerve paralysis were analyzed.
Eyelid closure is currently evaluated by systems primarily designed to assess lower/midfacial movements. The methods are subjective, difficult to reproduce, and measure only volitional closure. Reflex closure is responsible for eye hydration, and its evaluation demands dynamic analysis.
A 60Hz video camera incorporated into a helmet was used to analyze blinking. Reflective markers on the forehead and eyelids allowed for the dynamic measurement of the reflex blink. Eyelid displacement, velocity and acceleration were calculated. The degree of synchrony between bilateral blinks was also determined.
This study demonstrates that video motion analysis can describe normal and altered eyelid motions in a quantifiable manner.
To our knowledge, this is the first study to measure dynamic reflex blinks. Eyelid closure may now be evaluated in kinematic terms. This technique could increase understanding of eyelid motion and permit more accurate evaluation of eyelid function. Dynamic eyelid evaluation has immediate applications in the treatment of facial palsy affecting the reflex blink. Relevance No method has been developed that objectively quantifies dynamic eyelid closure. Methods currently in use evaluate only volitional eyelid closure, and are based on direct and indirect observer assessments. These methods are subjective and are incapable of analyzing dynamic eyelid movements, which are critical to maintenance of corneal hydration and comfort. A system that quantifies eyelid kinematics can provide a functional analysis of blink disorders and an objective evaluation of their treatment(s).
演示计算机化眼睑运动分析如何量化人类反射性眨眼。
对17名正常受试者和10名单侧面神经麻痹患者进行分析。
目前评估眼睑闭合主要通过主要设计用于评估面下部/中部运动的系统。这些方法主观、难以重复,且仅测量随意性闭合。反射性闭合对眼睛保湿很重要,其评估需要动态分析。
使用安装在头盔中的60Hz摄像机分析眨眼。前额和眼睑上的反光标记可用于动态测量反射性眨眼。计算眼睑位移、速度和加速度。还确定了双侧眨眼之间的同步程度。
本研究表明视频运动分析可以以可量化的方式描述正常和异常的眼睑运动。
据我们所知,这是第一项测量动态反射性眨眼的研究。现在可以从运动学角度评估眼睑闭合。这项技术可以增进对眼睑运动的理解,并允许更准确地评估眼睑功能。动态眼睑评估在影响反射性眨眼的面瘫治疗中具有直接应用。相关性目前尚未开发出客观量化动态眼睑闭合的方法。目前使用的方法仅评估随意性眼睑闭合,且基于直接和间接的观察者评估。这些方法主观,无法分析对维持角膜保湿和舒适度至关重要的动态眼睑运动。量化眼睑运动学的系统可以提供眨眼障碍的功能分析及其治疗的客观评估。