Suppr超能文献

采用四极杆离子阱气相色谱-质谱联用仪测定二噁英/呋喃和多氯联苯。

Determination of dioxins/furans and PCBs by quadrupole ion-trap gas chromatography-mass spectrometry.

作者信息

Plomley J B, Lausevic M, March R E

机构信息

MDS SCIEX, Concord, Ontario, Canada.

出版信息

Mass Spectrom Rev. 2000 Sep-Oct;19(5):305-65. doi: 10.1002/1098-2787(2000)19:5<305::AID-MAS4>3.0.CO;2-T.

Abstract

The versatility and sensitivity of the quadrupole ion trap tandem mass spectrometer has been applied to the determination of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzofurans (PCDFs), and of polychlorinated biphenyls (PCBs). A brief introduction to the theory of ion confinement in a quadrupole ion trap permits discussion of ion trajectory stability, mass-selective ion ejection, the frequencies of ion motion, and the role of resonant excitation of ion motion. The tandem mass spectrometric examination of PCDDs and PCDFs eluting and co-eluting from a gas chromatographic column is described. Illustrative examples are given of the analysis of field samples containing PCDDs and PCDFs. A comparison is presented of the performance of each of a quadrupole ion trap tandem mass spectrometer, a triple stage quadrupole mass spectrometer, and a sector instrument of relatively high mass resolution for the determination of PCDDs and PCDFs. This comparison is made with respect to instrument tuning, calibration plots, detection limits, ion signals at low concentration, relative response factors, ionization cross-sections, and the examination of field samples. The application of quadrupole ion trap tandem mass spectrometry to the examination of PCBs is focused upon those PCB congeners that have the greatest toxicity. 39 congeners of the total of 209 PCB congeners have been identified as having the greatest toxicities. Chemical ionization has been used for the determination of co-eluting congeners #77 and #110 where the toxicity of the former is much greater than that of the latter. An analytical protocol, based on the variation of molecular ion fragmentation according to the degree (or absence) of chlorine ortho-substitution, has been proposed for distinguishing between toxic and nontoxic PCB congeners.

摘要

四极杆离子阱串联质谱仪的多功能性和灵敏度已应用于多氯代二苯并 - 对 - 二噁英(PCDDs)、多氯代二苯并呋喃(PCDFs)以及多氯联苯(PCBs)的测定。简要介绍四极杆离子阱中的离子限制理论,有助于讨论离子轨迹稳定性、质量选择性离子喷射、离子运动频率以及离子运动共振激发的作用。描述了从气相色谱柱洗脱和共洗脱的PCDDs和PCDFs的串联质谱检测。给出了含有PCDDs和PCDFs的现场样品分析的示例。比较了四极杆离子阱串联质谱仪、三级四极杆质谱仪和相对高质量分辨率的扇形仪器在测定PCDDs和PCDFs方面的性能。这种比较涉及仪器调谐、校准曲线、检测限、低浓度下的离子信号、相对响应因子、电离截面以及现场样品检测。四极杆离子阱串联质谱在PCBs检测中的应用重点关注毒性最大的那些PCB同系物。在总共209种PCB同系物中,已鉴定出39种具有最大毒性。化学电离已用于测定共洗脱的同系物#77和#110,其中前者的毒性远大于后者。已提出一种基于分子离子碎片随氯邻位取代程度(或有无)变化的分析方案,用于区分有毒和无毒的PCB同系物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验