• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Programmable control of column selectivity for temperature-programmed GC.

作者信息

Coutant C, Sacks R

机构信息

Department of Chemistry, University of Michigan, Ann Arbor 48109, USA.

出版信息

Anal Chem. 2000 Nov 1;72(21):5450-8. doi: 10.1021/ac000610h.

DOI:10.1021/ac000610h
PMID:11080900
Abstract

A computer-driven pressure controller connected to the junction point of a series-coupled ensemble of two capillary GC columns having different stationary-phase selectivity is used to obtain on-the-fly (programmable) changes in ensemble selectivity. Changes in the junction-point pressure result in differential changes in the local carrier gas velocity in the two columns, and this results in changes in the pattern of peaks eluting from the ensemble. When used with relatively fast temperature programming (30 degrees C/min), the pattern of eluting peaks can be very sensitive to the time at which a selectivity (junction-point pressure) change is implemented. These elution pattern changes are described for a set of six PCB congeners that elute with a small range of retention times. The components are considered as a group, and changes in their elution pattern are described for a single junction-point pressure change, which is implemented at various times after sample injection. If the pressure change is implemented after the components have migrated across the junction point, the final pressure has relatively little impact on the ensemble retention pattern. Pressure changes implemented prior to the components reaching the junction can have a large effect and usually result in a pattern of peaks similar to the pattern obtained when the final pressure is used for the entire separation. For pressure changes made when the group of components is near the junction point, the observed peak pattern may be very sensitive to the time of the pressure change. The time at which the junction-point pressure change occurs is varied in 1.0-s intervals. Artifacts such as peak doubling and peak focusing or broadening are observed if a migrating band is crossing the column junction point at the time of the programmed pressure change.

摘要

相似文献

1
Programmable control of column selectivity for temperature-programmed GC.
Anal Chem. 2000 Nov 1;72(21):5450-8. doi: 10.1021/ac000610h.
2
Pressure-tunable column selectivity for high-speed vacuum-outlet GC.用于高速真空出口气相色谱的压力可调柱选择性
Anal Chem. 2000 Jun 1;72(11):2507-13. doi: 10.1021/ac991246t.
3
Column Selectivity Programming and Fast Temperature Programming for High-Speed GC Analysis of Purgeable Organic Compounds.
Anal Chem. 1998 Dec 1;70(23):4960-6. doi: 10.1021/ac980463b.
4
A tandem column ensemble with an atmospheric pressure junction-point vent for high-speed GC with selective control of peak-pair separation.
Anal Chem. 2001 Feb 15;73(4):813-9. doi: 10.1021/ac001028w.
5
Pulsed flow modulation for high-speed GC using a pressure-tunable column ensemble.
Anal Chem. 2001 Jan 15;73(2):279-85. doi: 10.1021/ac000665j.
6
Band-trajectory model for temperature-programmed series-coupled column ensembles with pressure-tunable selectivity.
Anal Chem. 2001 Jul 1;73(13):3112-8. doi: 10.1021/ac010136v.
7
High-speed analysis of complex indoor VOC mixtures by vacuum-outlet GC with air carrier gas and programmable retention.采用带空气载气和可编程保留功能的真空出口气相色谱法对复杂室内挥发性有机化合物混合物进行快速分析。
Environ Sci Technol. 2001 Jan 1;35(1):163-9. doi: 10.1021/es001255f.
8
Programmable selectivity for GC with series-coupled columns using pulsed heating of the second column.使用第二根色谱柱的脉冲加热对串联耦合色谱柱进行气相色谱的可编程选择性。
Anal Chem. 2003 May 15;75(10):2215-23. doi: 10.1021/ac020614h.
9
Stop-flow programmable selectivity with a dual-column ensemble of microfabricated etched silicon columns and air as carrier gas.采用微加工蚀刻硅柱双柱组合和空气作为载气的停流可编程选择性。
Anal Chem. 2005 Apr 1;77(7):2078-84. doi: 10.1021/ac040174p.
10
Pressure Tuning of First Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography.一维柱在全二维气相色谱中的压力调谐。
Anal Chem. 2016 Sep 20;88(18):9087-94. doi: 10.1021/acs.analchem.6b02017. Epub 2016 Aug 29.