Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine.

作者信息

Deb S, Martin B, Sun L, Burris D, Wherry D, Pikoulis E, Rhee P

机构信息

Department of Surgery, National Naval Medical Center, Bethesda, MD 20814, USA.

出版信息

Chest. 2000 Dec;118(6):1762-8. doi: 10.1378/chest.118.6.1762.

DOI:10.1378/chest.118.6.1762
PMID:11115470
Abstract

OBJECTIVE

Devices that reduce technical difficulty and anastigmatic time when repairing large vessels such as the thoracic aorta would be beneficial. The aim of this study was to determine if titanium vascular closure staples (3 mm) could be safely and quickly applied in the repair of large vessels such as the thoracic aorta.

DESIGN

Through a left thoracotomy in 10 female swine (110 to 130 lb), an interposition graft (14 to 16 mm textile) was placed into the aorta distal to the left subclavian artery. Animals were randomized at the time of repair to either running sutures (n = 5; 6-0 polypropylene) or vascular closure staples (n = 5; 3 mm). The anastomosis was evaluated after 2 months with aortograms, and the aorta was harvested to evaluate healing.

RESULTS

The clamp times (mean +/- SD) were 30.8 +/- 8.2 min for suture repair and 24.8 +/- 5.1 min for vascular closure staple repair (p = 0.2). Anastomosis times were 20. 0 +/- 6.2 min for the suture group and 16.4 +/- 6.4 min for the vascular closure staple group (p = 0.4). Arch aortograms at 2 months revealed no significant difference in luminal narrowing between the two groups. Gross and microscopic examination revealed no thrombosis, well-healed wounds with a continuous intimal layer, and no differences in intimal thickness or inflammation between the two groups.

CONCLUSION

Vascular closure staples were equivalent to sutures in terms of durability, graft patency, and wound healing at 2 months. Vascular closure staples may offer the trauma surgeon a quick and easy alternative when repairing large vessels such as the thoracic aorta.

摘要

相似文献

1
Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine.
Chest. 2000 Dec;118(6):1762-8. doi: 10.1378/chest.118.6.1762.
2
Vascular closure stapler clip anastomosis decreases aortic cross-clamping time compared to interrupted nonabsorbable and running absorbable sutures in growing pigs.
Ann Vasc Surg. 2006 Jan;20(1):35-41. doi: 10.1007/s10016-005-9321-z.
3
Arterial reconstruction with vascular clips is safe and quicker than sutured repair.使用血管夹进行动脉重建比缝合修复更安全、更快。
Cardiovasc Surg. 1998 Dec;6(6):573-8. doi: 10.1016/s0967-2109(98)00071-4.
4
Common bile duct repair with titanium staples. Comparison with suture closure.用钛钉进行胆总管修复。与缝合关闭的比较。
Surg Endosc. 1997 Jul;11(7):714-7. doi: 10.1007/s004649900434.
5
Ureteral repair with titanium staples: comparison with suture closure.用钛钉进行输尿管修复:与缝合闭合的比较。
Urology. 1998 Apr;51(4):553-7. doi: 10.1016/s0090-4295(97)00694-8.
6
Vein patch angioplasty with non-penetrating titanium clips. Comparison to standard suture technique.使用非穿透性钛夹的静脉补片血管成形术。与标准缝合技术的比较。
Acta Chir Belg. 2009 Nov-Dec;109(6):756-9. doi: 10.1080/00015458.2009.11680530.
7
Arterial and venous repair with vascular clips: comparison with suture closure.使用血管夹进行动静脉修复:与缝合闭合的比较。
J Vasc Surg. 1997 Jul;26(1):24-8. doi: 10.1016/s0741-5214(97)70142-3.
8
The influence of absorbable subcuticular staples, continuous subcuticular absorbable suture, and percutaneous metal skin staples on infection in contaminated wounds.可吸收皮下缝合钉、连续皮下可吸收缝线及经皮金属皮肤缝合钉对污染伤口感染的影响
J Long Term Eff Med Implants. 2012;22(2):145-55. doi: 10.1615/jlongtermeffmedimplants.v22.i2.50.
9
Arterial repair with synthetic patch by using titanium clips.使用钛夹进行合成补片动脉修复术。
J Trauma. 2000 Feb;48(2):292-5. doi: 10.1097/00005373-200002000-00016.
10
[Metal staples versus conventional suture for wound closure in total knee arthroplasty].[全膝关节置换术中金属吻合钉与传统缝线用于伤口闭合的比较]
Acta Chir Orthop Traumatol Cech. 2014;81(3):233-7.

引用本文的文献

1
Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis.一种用于无缝合主动脉吻合术的新型环形连接器的生物力学特性
J Biomed Res. 2018 Nov 20;32(5):454-460. doi: 10.7555/JBR.31.20170011.
2
Combat casualty care research: from bench to the battlefield.战斗伤员护理研究:从实验室到战场
World J Surg. 2005;29 Suppl 1:S7-11. doi: 10.1007/s00268-004-2052-4.