Suppr超能文献

负离子和正离子电喷雾串联质谱用于液相色谱串联质谱分析氧化脱氧核苷的比较。

Comparison of negative and positive ion electrospray tandem mass spectrometry for the liquid chromatography tandem mass spectrometry analysis of oxidized deoxynucleosides.

作者信息

Hua Y, Wainhaus S B, Yang Y, Shen L, Xiong Y, Xu X, Zhang F, Bolton J L, van Breemen R B

机构信息

Department of Medicinal Chemistry and Pharmacognosy, College of Pharmacy, University of Illinois at Chicago, 60612-7231, USA.

出版信息

J Am Soc Mass Spectrom. 2001 Jan;12(1):80-7. doi: 10.1016/S1044-0305(00)00191-4.

Abstract

Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxy-methyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90]-. The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C8 position, an S1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides.

摘要

氧化脱氧核苷被广泛用作DNA氧化和氧化应激评估的生物标志物。尽管气相色谱质谱法被广泛用于多种DNA损伤的测量,但这种方法需要复杂的样品制备,这可能导致人为氧化。为了解决这些问题,开发了一种高效液相色谱(HPLC)-串联质谱(LC-MS/MS)方法,用于快速制备样品的DNA样品中8-羟基-2'-脱氧鸟苷(8-OH-dG)、8-羟基-2'-脱氧腺苷(8-OH-dA)、2-羟基-2'-脱氧腺苷(2-OH-dA)、胸苷二醇(TG)和5-羟基甲基-2'-脱氧尿苷(HMDU)的测量。为了在定量LC-MS/MS分析期间以最佳灵敏度选择性监测这些前体的产物离子,必须在具有碰撞诱导解离(CID)的MS/MS期间识别独特且丰富的碎片离子。比较了具有CID的正离子和负离子电喷雾串联质谱用于这五种氧化脱氧核苷的分析。在正离子和负离子模式下,最丰富的碎片离子通常是由糖苷键的断裂形成的。然而,在8-OH-dG、2-OH-dA和8-OH-dA的负离子电喷雾串联质谱中,糖环内两个键的断裂产生了大量的S1型离子,损失了一个重90 u的中性分子,[M - H - 90]-。除了胸苷二醇在负离子模式下信噪比高100倍外,负离子和正离子电喷雾MS/MS的信噪比相似。因此,对于包括胸苷二醇的氧化脱氧核苷组的分析,具有CID的负离子电喷雾串联质谱比正离子模式更可取。对碎裂途径的研究表明了带负电荷的氧化核苷碎裂的一些新的一般规则。当嘌呤核苷在C8位置含有羟基时,由于六元环氢转移过程,S1型产物离子将在产物离子中占主导地位。最后,在所有三种氧化嘌呤核苷中都观察到了一种通过从糖部分消除一个重48(CO2H4)的中性分子而形成的新型碎片离子。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验