Suppr超能文献

一种使用IMP和SPECT在无需任何采血情况下估算局部脑血流量的新方法。

A new method to estimate rCBF using IMP and SPECT without any blood sampling.

作者信息

Nishizawa S, Shiozaki T, Ueno M, Toyoda H, Shimono T, Kamoto Y, Fujita T, Yonekura Y, Konishi J

机构信息

Department of Nuclear Medicine and Diagnostic Imaging, Graduate School of Medicine, Kyoto University, Japan.

出版信息

Ann Nucl Med. 2000 Dec;14(6):433-40. doi: 10.1007/BF02988289.

Abstract

We developed and evaluated a method to measure rCBF without any blood sampling by using iodine- 123 IMP and SPECT. An integral of arterial input function, the integral taken from the value 0 to T of the variable Ca(t)dt, can be expressed as TC(T)/CO, where TC(T) is radioactivity delivered to the body in T minutes and CO is cardiac output. If T is acceptably small, rCBF can be determined by means of a microsphere model analysis with IMP as Cb(T)/(TC(T)/CO), where Cb(T) is cerebral radioactivity at T minutes. We derived TC(T) and CO from a chest dynamic scan. The method was applied to 45 patients who underwent rCBF studies (58 studies) with arterial blood sampling (ABS). Data from the chest scan were analyzed in comparison with ABS data in the first 28 studies, and equations for correction yielding an accurate TC(T)/CO were derived. The validity of the proposed method was evaluated in the subsequent 30 studies. The method yielded rCBF (rCBF-test) which agreed well with rCBF obtained by a two-compartment model analysis of dynamic SPECT and ABS data (rCBF-ref) with the mean and SD of differences between rCBF-test and rCBF-ref being 1.0 and 2.7 ml/100 g/min, respectively. In eleven subjects who underwent more than two studies, a percentage change in rCBF-test between the studies also closely approximated that of rCBF-ref (y = 1.11 x + 2.63, r = 0.92). The method can be used with acceptable reliability to measure rCBF without any blood sampling.

摘要

我们开发并评估了一种通过使用碘 - 123异碘安非他明(IMP)和单光子发射计算机断层扫描(SPECT)在无需任何采血的情况下测量局部脑血流量(rCBF)的方法。动脉输入函数的积分,即从变量Ca(t)dt的值0到T所取的积分,可以表示为TC(T)/CO,其中TC(T)是在T分钟内输送到身体的放射性,CO是心输出量。如果T足够小,rCBF可以通过以IMP作为Cb(T)/(TC(T)/CO)的微球模型分析来确定,其中Cb(T)是T分钟时的脑放射性。我们从胸部动态扫描中得出TC(T)和CO。该方法应用于45例接受rCBF研究(58项研究)并进行动脉采血(ABS)的患者。在前28项研究中,将胸部扫描数据与ABS数据进行比较分析,并得出用于校正以获得准确的TC(T)/CO的方程。在随后的30项研究中评估了所提出方法的有效性。该方法得出的rCBF(rCBF - test)与通过对动态SPECT和ABS数据进行双室模型分析获得的rCBF(rCBF - ref)非常吻合,rCBF - test和rCBF - ref之间差异的平均值和标准差分别为1.0和2.7 ml/100 g/min。在接受两项以上研究的11名受试者中,各研究之间rCBF - test的百分比变化也与rCBF - ref的百分比变化非常接近(y = 1.11x + 2.63,r = 0.92)。该方法可用于在无需任何采血的情况下以可接受的可靠性测量rCBF。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验