Schneeweiss S, Sangha O, Siebert H, Hübner M, Fuhrmann J, Wildner M, Witte J
Bayerischer Forschungsverbund Public Health und Institut für Medizinische Informationsverarbeitung, Biometrie und Epidemiologie (IBE), Ludwig-Maximilians-Universität, München.
Soz Praventivmed. 2000;45(6):258-66. doi: 10.1007/BF01591688.
During the past years, the assessment of the appropriateness of hospital utilization has become increasingly important in the German health care system. Previous evaluations by regional review organizations in several states demonstrated the need for a standardized, reliable, and valid instrument to evaluate the appropriateness of inpatient care. Objective of the study is to test the reliability of a German adaptation of the "Appropriateness Evaluation Protocol" (AEP). Among all 2672 admissions from the department of surgery of a regional medical center during one calendar year, 54 patients were randomly selected to evaluate the inter-rater reliability and 51 patients to test intra-rater reliability. Overall agreement, specific agreement and Kappa statistics were estimated for every hospital admissions and all consecutive hospital days. The German AEP showed an inter-rater agreement of 74% (62-86%) for hospital admissions (Kappa = 0.44) and 84% (79%-88%) for all hospital days (K = 0.55). Intra-rater reliability was 88% (79%-97%) for hospital admissions (K = 0.60) and 88% (85%-92%) for all hospital days (K = 0.70). The observed agreement is independent of length of hospital stay and proportion of appropriate days. A standardized instrument with known metric properties is essential for quality management in hospitals to prepare for an increasingly consolidating health care market in Germany. The German AEP is a reliable instrument, which will allow to identify inefficiencies in the management of surgical inpatients.
在过去几年中,医院利用合理性评估在德国医疗保健系统中变得越来越重要。几个州的地区审查组织先前的评估表明,需要一种标准化、可靠且有效的工具来评估住院护理的合理性。本研究的目的是测试德国版“合理性评估协议”(AEP)的可靠性。在一个日历年内,从一家地区医疗中心外科的所有2672例入院病例中,随机选择54例患者评估评分者间信度,51例患者测试评分者内信度。对每例入院病例和所有连续住院日估计总体一致性、具体一致性和Kappa统计量。德国版AEP在入院病例方面显示评分者间一致性为74%(62%-86%)(Kappa = 0.44),在所有住院日方面为84%(79%-88%)(K = 0.55)。评分者内信度在入院病例方面为88%(79%-97%)(K = 0.60),在所有住院日方面为88%(85%-92%)(K = 0.70)。观察到的一致性与住院时间和合理天数的比例无关。对于德国日益整合的医疗保健市场中的医院质量管理而言,具有已知度量属性的标准化工具至关重要。德国版AEP是一种可靠的工具,它将有助于识别外科住院患者管理中的低效率情况。