• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Nonchromatographic radioimmunoassay of plasma 11-deoxycortisol, for use in the metyrapone test, with polyethylene glycol as the precipant.

作者信息

Lee L M, Schiller H S

出版信息

Clin Chem. 1975 May;21(6):719-24.

PMID:1122615
Abstract

We have developed a simple, reliable radioimmunoassay for plasma 11-deoxycortisol. The method does not require chromatography but instead makes use of a simple extraction procedure which, in combination with the antibody characteristics, is highly specific for the metyrapone test. Polyethylene glycol was used to separate free and antibody-bound steroid. The smallest amount measurable is 15 pg (2.0 mug/liter of plasma). The method is shown to be precise and accurate. Intraassay precision of the method for two plasma pools was 26.7 plus or minus 2.5 mug/liter (CV equals 9.4%) and 61.2 plus or minus 3.7 mug/liter (CV equals 6.0%). The respective inter-assay precision was 27.0 plus or minus 1.7 mug/liter (CV equals 6.3%) and 59.9 plus or minus 2.3 mug/liter (CV equals 3.8%). The validity of the assay was further verified by evaluating the plasma 11-deoxycortisol response to metyrapone administration. The relative simplicity of the method and the commercial availability of all reagents, including antisera, makes this radioimmunoassay procedure practical for use in clinical laboratories.

摘要

相似文献

1
Nonchromatographic radioimmunoassay of plasma 11-deoxycortisol, for use in the metyrapone test, with polyethylene glycol as the precipant.
Clin Chem. 1975 May;21(6):719-24.
2
[A radioimmunoassay for plasma 11-desoxycortisol and its use in the rapid metopirone test].
Endokrinologie. 1978 Feb;71(1):60-4.
3
Radioimmunoassay for 11-deoxycortisol using iodine-labeled tracer.
Endocrinol Jpn. 1976 Aug;23(4):359-63.
4
Parallel radioimmunoassay for plasma cortisol and 11-deoxycortisol.血浆皮质醇和11-脱氧皮质醇的平行放射免疫测定法。
Clin Chem. 1975 Oct;21(11):1644-7.
5
Radioimmunoassay of plasma testosterone, with use of polyethylene glycol to separate antibody-bound and free hormone.采用聚乙二醇分离抗体结合型和游离型激素,对血浆睾酮进行放射免疫测定。
Clin Chem. 1975 May;21(6):708-14.
6
A simple radioimmunoassay for plasma cortisol and 11-deoxycortisol (17, 21-dihydroxy-4-pregnene-3, 20-dione).
Steroids. 1976 Oct;28(4):487-98. doi: 10.1016/0039-128x(76)90018-0.
7
Improved radioimmunoassay for 11-deoxycortisol (compound S) in plasma.
Clin Chem. 1979 Oct;25(10):1704-7.
8
A simplified radioimmunoassay for plasma 11-deoxycortisol.
Clin Biochem. 1981 Apr;14(2):47-50. doi: 10.1016/s0009-9120(81)90636-6.
9
Solid phase fluoroimmunoassay for 11-deoxycortisol in serum using 21-amino-17-hydroxyprogesterone.使用21-氨基-17-羟孕酮的血清11-脱氧皮质醇固相荧光免疫测定法。
Steroids. 1982 Oct;40(4):393-401. doi: 10.1016/0039-128x(82)90017-4.
10
A competitive enzyme-linked immunosorbent assay for plasma 11-deoxycortisol (17,21-dihydroxy-4-pregnene-3,20-dione).一种用于检测血浆11-脱氧皮质醇(17,21-二羟基-4-孕烯-3,20-二酮)的竞争性酶联免疫吸附测定法。
Steroids. 1986 Jun;47(6):365-72. doi: 10.1016/0039-128x(86)90052-8.