Accurate determination of the elastic modulus of surgical bone cements is of primary importance, when evaluating the stresses within the cement mantle in Total Joint Arthroplasty. This article presents a new method of determining the modulus of surgical bone cements from the biaxial flexural test. The biaxial flexural test is not currently employed in mainstream orthopedic mechanical testing, which is surprising because most loading in orthopedic applications is biaxial in nature. Nor has this method been utilized for dental materials, even though the biaxial flexure test has been used for many years in this field. It has been demonstrated that the modulus of surgical bone cements can be determined from the biaxial flexural test, and these results are in agreement with results from compressive and bending tests.
在评估全关节置换术中骨水泥套的应力时,准确测定外科骨水泥的弹性模量至关重要。本文提出了一种通过双轴弯曲试验测定外科骨水泥模量的新方法。目前,双轴弯曲试验在主流骨科力学测试中并未得到应用,这令人惊讶,因为骨科应用中的大多数载荷本质上是双轴的。而且,即使双轴弯曲试验在牙科材料领域已使用多年,该方法也未被用于牙科材料。已经证明,可以通过双轴弯曲试验确定外科骨水泥的模量,并且这些结果与压缩和弯曲试验的结果一致。