Image quality and dose in film-screen magnification mammography.

作者信息

McParland B J

机构信息

Department of Medical Imaging-1528, King Fahad National Guard Hospital, PO Box 22490, Riyadh, Saudi Arabia 11426.

出版信息

Br J Radiol. 2000 Oct;73(874):1068-77. doi: 10.1259/bjr.73.874.11271899.

DOI:10.1259/bjr.73.874.11271899
PMID:11271899
Abstract

Extended exposure times in magnification mammography are a result of the reduced X-ray tube currents required for a small focal spot. The consequences of this are the potential for reduced image quality through motion blur during exposure as well as the onset of film reciprocity law failure. Previous investigators have suggested increasing the X-ray tube potential as a practical mechanism for reducing exposure times in magnification mammography and have demonstrated negligible image quality degradation at least up to 32 kVp. This paper describes a film-screen magnification mammography study that expands upon this previous work to investigate the magnitude of the reduction of breast mean glandular dose and exposure time and the changes in subjective image quality (visibility of low contrast details in an RMI 152 phantom) with increases in tube potential between 28 kVp and 35 kVp. Measures of changes in the radiographic contrast and in the scatter-to-primary ratio (SPR) in magnification geometry as a function of tube potential were also obtained. Evidence for reciprocity law failure was also assessed. For a constant film optical density, increasing the X-ray tube potential from 28 kVp to 35 kVp reduced the mean glandular dose from 3.9 mGy to 2.7 mGy and reduced the exposure time from 3.2 s to 1.0 s. Over this range, the detection rate of fibrils and microcalcification-mimicking specks did not vary with tube potential at the 0.05 level of significance. It was found that only the low contrast mass detail detection rate at 35 kVp was significantly less than that at 28 kVp. The measured radiographic contrast decreased with tube potential and the SPR increased with tube potential. However, both changes were weak, and linear regressions determined that the 95% confidence intervals of the slopes relating both contrast and SPR with tube potential encompassed zero. It is concluded that magnification mammography performed at 34 kVp yields significant reductions in exposure time and mean glandular dose, with a detail detection capability similar to that at 28 kVp.

摘要

相似文献

1
Image quality and dose in film-screen magnification mammography.
Br J Radiol. 2000 Oct;73(874):1068-77. doi: 10.1259/bjr.73.874.11271899.
2
A comparison of fixed and variable kVp technique protocols for film-screen mammography.乳腺X线摄影中固定千伏峰值和可变千伏峰值技术方案的比较。
Br J Radiol. 2000 Jun;73(870):613-26. doi: 10.1259/bjr.73.870.10911785.
3
Optimal technique factors for magnification mammography.
Invest Radiol. 1997 Jul;32(7):378-81. doi: 10.1097/00004424-199707000-00002.
4
Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system.数字乳腺摄影成像系统的剂量与图像质量特性的实验研究
Med Phys. 2003 Mar;30(3):442-8. doi: 10.1118/1.1543572.
5
Low dose high energy x-ray in-line phase sensitive imaging prototype: Investigation of optimal geometric conditions and design parameters.低剂量高能X射线在线相敏成像原型:最佳几何条件和设计参数的研究。
J Xray Sci Technol. 2015;23(6):667-82. doi: 10.3233/XST-150519.
6
Radiographic techniques in screen-film mammography.屏-片乳腺摄影中的放射技术。
J Appl Clin Med Phys. 2002 Summer;3(3):248-54. doi: 10.1120/jacmp.v3i3.2572.
7
Image quality in mammography with special reference to anti-scatter grids and the magnification technique.
Acta Radiol Diagn (Stockh). 1986 Jul-Aug;27(4):467-79. doi: 10.1177/028418518602700420.
8
Optimization of tube potential-filter combinations for film-screen mammography: a contrast detail phantom study.乳腺钼靶摄影中管电压-滤过组合的优化:一项对比细节模体研究
Clin Imaging. 2005 Jul-Aug;29(4):246-50. doi: 10.1016/j.clinimag.2004.11.003.
9
Mammography in New Zealand: radiation dose and image quality.新西兰的乳腺钼靶检查:辐射剂量与图像质量。
Australas Phys Eng Sci Med. 1991 Jun;14(2):97-102.
10
[X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-].[使用具有小焦点的X射线管进行X射线相位成像——乳腺摄影图像质量的改善——]
Igaku Butsuri. 2002;22(1):21-9.

引用本文的文献

1
Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography.在诊断人群中使用专用乳腺 CT 进行个体化辐射剂量估算,并与诊断性乳房 X 光摄影进行比较。
Phys Med Biol. 2013 Nov 21;58(22):7921-36. doi: 10.1088/0031-9155/58/22/7921. Epub 2013 Oct 29.
2
Reconstruction of absorbed doses to fibroglandular tissue of the breast of women undergoing mammography (1960 to the present).重建接受乳房 X 光摄影检查的女性乳房纤维腺体组织的吸收剂量(1960 年至今)。
Radiat Res. 2012 Jan;177(1):92-108. doi: 10.1667/rr2241.1. Epub 2011 Oct 12.