To determine whether emergency medical services (EMS) systems adhere to accepted equipment hygiene standards.
Mail surveys were sent to the physician medical directors of the EMS systems of the 125 most populous cities in the United States.
Eighty-five surveys (68%) were returned. Seventy-three (86%) of the responding services have a policy addressing equipment decontamination, and 32 of these (44%) have an accompanying quality assurance program. Seventy-nine (93%) utilize either alcohol or a commercial disinfectant (A/CD) on noncritical items when visibly contaminated with blood. However, only 32 of those agencies (41%) use soap and water in addition to A/CD. Another nine (11%) exchange contaminated items at the hospital, one (1%) uses other methods, and two (2%) respondents did not know. Seventy-six (89%) of the responding agencies perform endotracheal intubation. Of the 54 that decontaminate their own blades, 20 (37%) use soap and water in addition to A/CD, 32 (59%) use A/CD alone, and two (4%) use soap and water alone.
Adherence to accepted hygiene standards among EMS systems in our most populous cities is poor. Many systems do not use soap and water prior to A/CD. Failure to do so may minimize the effectiveness of disinfection. Several systems use A/CD or soap and water alone, neither of which meets current standards for high-level disinfection recommended for items that will come in contact with mucous membranes, such as laryngoscope blades.
确定紧急医疗服务(EMS)系统是否遵守公认的设备卫生标准。
向美国125个人口最多城市的EMS系统的医师医疗主任发送邮件调查。
共收回85份调查问卷(68%)。73份(86%)回复的服务机构有关于设备去污的政策,其中32份(44%)有配套的质量保证计划。79份(93%)在非关键物品明显被血液污染时使用酒精或商用消毒剂(A/CD)。然而,这些机构中只有32份(41%)除A/CD外还使用肥皂和水。另外9份(11%)在医院更换被污染的物品,1份(1%)使用其他方法,2份(2%)受访者表示不知道。76份(89%)回复的机构进行气管插管。在54份自行对喉镜叶片进行去污的机构中,20份(37%)除A/CD外还使用肥皂和水,32份(59%)仅使用A/CD,2份(4%)仅使用肥皂和水。
我国人口最多城市的EMS系统对公认卫生标准的遵守情况较差。许多系统在使用A/CD之前不使用肥皂和水。不这样做可能会降低消毒效果。有几个系统仅使用A/CD或肥皂和水,这两种方法都不符合目前针对将与黏膜接触的物品(如喉镜叶片)推荐的高水平消毒标准。