Yap A U, Ng S C, Siow K S
Department of Restorative Dentistry, National University of Singapore, Singapore 119074, Republic of Singapore.
Oper Dent. 2001 May-Jun;26(3):260-6.
This study investigated the influence of soft-start polymerization on the effectiveness of cure and post-gel shrinkage of a visible light cured resin composite (Z100). Three cure modes (LH-high intensity; LA-soft-start polymerization involving step-wise modulation of light intensity and LL-low intensity) of a commercial light-cure unit (Kavo PolyLUX II) were examined and compared to another light-cure unit (Spectrum). The effectiveness of cure with the different cure modes was assessed by computing the hardness gradient between top and bottom surfaces of 2 mm composites specimens after different light exposure times. A strain-monitoring device was used to measure the linear polymerization shrinkage associated with the different cure modes and exposure times over 180 minutes. A sample size of five was used for both experiments. Data was analyzed using one-way ANOVA and Scheffe's post-hoc test at significance level 0.05. Results showed that effectiveness of cure generally increased with increase cure time. Although modulation of light energy intensity (LA 40/80 seconds) resulted in lower polymerization shrinkage compared to LH 40 seconds, no significant difference was observed between these three cure regimes. Curing with the Spectrum curing light resulted in the lowest polymerization shrinkage.
本研究调查了软启动聚合对可见光固化树脂复合材料(Z100)固化效果和凝胶后收缩率的影响。对一款商用光固化设备(卡瓦PolyLUX II)的三种固化模式(LH - 高强度;LA - 涉及光强逐步调制的软启动聚合;LL - 低强度)进行了检测,并与另一款光固化设备(Spectrum)进行比较。通过计算不同光照时间后2毫米复合材料试样顶面和底面之间的硬度梯度,评估不同固化模式的固化效果。使用应变监测装置测量180分钟内与不同固化模式和光照时间相关的线性聚合收缩率。两个实验均采用5个样本量。数据采用单因素方差分析和谢费尔事后检验进行分析,显著性水平为0.05。结果表明,固化效果通常随固化时间的增加而提高。尽管与LH 40秒相比,光能量强度调制(LA 40/80秒)导致聚合收缩率较低,但这三种固化方式之间未观察到显著差异。使用Spectrum固化灯进行固化导致聚合收缩率最低。